USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/20164
Title: The electrical resistance of acupuncture source points as a relevant factor for inner organ status
Authors: Mirescu, Stefan - Claudiu
Issue Date: 2010
Publisher: Nicolae Testemitanu State Medical and Pharmaceutical University
Citation: MIRESCU, Stefan - Claudiu. The electrical resistance of acupuncture source points as a relevant factor for inner organ status. In: MedEspera: the 3rd Internat. Medical Congress for Students and Young Doctors: abstract book. Chișinău: S. n., 2010, pp. 20-21.
Abstract: The acupuncture source points have been known in the traditional Chinese medicine for about 5000 years and various therapies and diagnostic methods have been applied using them. Studies indicate that these points also express electrical modifications, depending on the health status of the individual. Aim. The aim of the paper is to study the relevance of electrical resistance measurements in these points in distinguishing inner organ changes. The study was conducted on patients from the gastroenterological department. The electrical resistance of the source points was measured using a Wheatstone bridge, of our own manufacturing, based on certain acupuncture maps. The data was collected using disposable Ag/AgCl electrodes and the results of the measurements were compared with the standard diagnosis test results. The statistical interpretation was performed using Microsoft Excel and GraphPad. The measured electrical resistance was between 23 and 600 kilo ohms, with considerable variations from a patient to another. Patients with organ resections (gall bladder, kidney, stomach) expressed a decreased electrical resistance in the source points corresponding to these organs (the gall bladder point etc.). Also, patients with cardiac failure expressed a modified electrical resistance in the heart source point, but also in the pulmonary point, probably anticipating the pulmonary stasis consecutive to the heart disease. Gall bladder lithiasis, hepatic cirrhosis and rheumatism also expressed altered electrical resistance in the correspondent points. Patients with inner organ diseases expressed modified electrical resistance in corresponding source points. Further studies will be conducted to test the accuracy of this method to distinguish specific inner organ pathologies and to test the applicability of this measurement as a screening instrument.
metadata.dc.relation.ispartof: MedEspera: The 3rd International Medical Congress for Students and Young Doctors, May 19-21, 2010, Chisinau, Republic of Moldova
URI: http://repository.usmf.md/handle/20.500.12710/20164
Appears in Collections:MedEspera 2010



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback