|
- IRMS - Nicolae Testemitanu SUMPh
- 2. FACULTATEA DE MEDICINĂ nr.1 / FACULTY OF MEDICINE nr.1
- Catedra de oftalmologie și optometrie
- 13th Black Sea Ophthalmological Congress, 29 October-1 November, 2015 Chisinau, Republic of Moldova
- 13th Black Sea Ophthalmological Congress, 29 October-1 November, 2015 Chisinau, Republic of Moldova
Please use this identifier to cite or link to this item:
http://hdl.handle.net/20.500.12710/24050
Title: | ISCRS in keratoconus |
Authors: | Dvali, M. Sirbiladze, B. Tsintsadze, N. Jankarashvili, N. |
Issue Date: | 2015 |
Publisher: | Black Sea Ophthalmological Society, Ophthalmological Association from Moldova, Nicolae Testemitanu State University of Medicine and Pharmacy of the Republic of Moldova |
Citation: | DVALI, M., SIRBILADZE, B., TSINTSADZE, N., JANKARASHVILI, N. ISCRS in keratoconus. In: 13th Black Sea Ophthalmological Society Congress, 29 October-1 November, 2015, Chisinau, Republic of Moldova: abstract book, 2015, p. 23. |
Abstract: | Purpose: To evaluate refractive effects of ISCR implantation in keratoconus patients.
Methods: The 1583 keratoconic eyes of 921 patients keratoconus (II-III st) were treated with ISCR
implantation with one or two segments according the special nomograms. Pre and post operative
examination included Snellen uncorrected distance visual acuity (UDVA) and CDVA, manifest
refraction, slitlamp biomicroscopy, fundus evaluation, ultrasound pachymetry, and corneal
topography and aberrometry Orbscan system.
Results: Pre Op: UCVA – 0.12 + 0.07; BCVA – 0.3 + 0.2; K-readers: 53.1 + 3.7 (steep meridian),
46.8 + 3.7 (flat meridian); PBFS – 54.75 + 1.9; SE – 7.2 + 3.5; astigmatism 6.1 + 1.5. Post Op:
UCVA – 0.7 + 0.2; BCVA – 0.7 + 0.2; K-readers: 45.9 + 3.7 (steep meridian), 42.8 + 2.7 (flat
meridian); PBFS – 51.0 + 2.1; SE – 2.0 + 1.5; astigmatism 2.5 + 0.7.
Conclusion: ISCS implantation improves all main parameters of corneal topography; it flattens
central optical zone, which results in increase of UCVA and remained stable over the follow-up
period. The reduction in segment diameter seems to be of great importance to better and effective
control of astigmatism. However, if the segments are nearer from the pupil margins, visual quality
can be adversely affected by scattered rays of light reaching the retina inducing blur and glares.
Therefore, a compromise between ring effect and visual quality should be found. Having 4 arclength
options (90, 120, 160 and 210 degrees) makes ISCRs to be more flexible in surgical
planning to achieve the better refractive outcomes. |
metadata.dc.relation.ispartof: | 13th Black Sea Ophthalmological Congress, 29 October-1 November, 2015 Chisinau, Republic of Moldova |
URI: | http://repository.usmf.md/handle/20.500.12710/24050 |
Appears in Collections: | 13th Black Sea Ophthalmological Congress, 29 October-1 November, 2015 Chisinau, Republic of Moldova
|
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
|