|
- IRMS - Nicolae Testemitanu SUMPh
- 1. COLECȚIA INSTITUȚIONALĂ
- MedEspera: International Medical Congress for Students and Young Doctors
- MedEspera 2024
Please use this identifier to cite or link to this item:
http://hdl.handle.net/20.500.12710/28530
Title: | Challenging clinical case |
Authors: | Savov, Petru |
Issue Date: | 2024 |
Publisher: | Instituţia Publică Universitatea de Stat de Medicină şi Farmacie „Nicolae Testemiţanu” din Republica Moldova |
Citation: | SAVOV, Petru. Challenging clinical case. In: MedEspera: the 10th Intern. Medical Congress for Stud. and Young Doctors, 24-27 April 2024: abstract book. Chișinău, 2024, p. 108. ISBN 978-9975-3544-2-4. |
Abstract: | Introduction. Atrial septal defect is a congenital disease characterized by the presence of communication between the right and left atria, leading to abnormal blood movement at the heart level. This defect occurs in 1 out of 1,500 newborns. There are several complications that can occur in the postoperative period, one of which we will talk about in this case. Case statement. In this work we present the case of an 18-year-old girl with a congenital atrial septal defect. An operation was performed in 2019 in order to eliminate the defect and perform a plastic repair of the tricuspid valve. In the postoperative period a complication such as a complete AV block was detected. To fix this complication during a preventive procedure a VVI Endurity type pacemaker (St. Jude/Abbott) was implanted. During the routine examination the patient underwent echocardiography which established that the ejection fraction was 30%. It was decided to implant a CRTD Solara (Medtronic) pacemaker on 11/20/2023. Discussions. During installation of the СRT-D pacemaker we encountered difficulties such as cannulation of the coronary sinus. We tried to fix this problem by using Guide wire floppy, but as its strength was not enough, we resorted to using Guide grand slam, because it is denser in its properties. As a result, coronary sinus cannulation was successfully performed, as well as the installation of atrial and ventricular leads. Conclusion. CRT-D remains the gold standard treatment for dilative CMP and this medical case is proof of that. communication between the right and left atria, leadin g to abnormal blood movement at the heart level. This defect occurs in 1 out of 1,500 newborns. There are several complications that can occur in the postoperative period, one of which we will talk ab out in this case. Case statement. In this work we present the case of an 18-year-old girl with a congenital atrial septal defect. An operation was performed in 2019 in order to el iminate the defect and perform a plastic repair of the tricuspid valve. In the postoperati ve period a complication such as a complete AV block was detected. To fix this complication during a preve ntive procedure a VVI Endurity type pacemaker (St. Jude/Abbott) was implanted. During the routine examination the patient underwent echocardiography which established that the ejection fraction was 30%. It was decided to implant a CRTD Solara (Medtronic) pacemaker on 11/20/2023. Discussions. During installation of the СRT-D pacemaker we encountered difficulties such as cannulation of the coronary sinus. We tried to fix this probl em by using Guide wire floppy, but as its strength was not enough, we resorted to using Guide grand sl am, because it is denser in its properties. As a result, coronary sinus cannulation was successfully performed, as well as the installation of atrial and ventricular leads. Conclusion. CRT-D remains the gold standard treatment for dilative CMP a nd this medical case is proof of that. |
metadata.dc.relation.ispartof: | MedEspera: The 10th International Medical Congress for Students and Young Doctors, 24-27 April 2024, Chișinău, Republic of Moldova |
URI: | https://medespera.md/en/books?page=10 http://repository.usmf.md/handle/20.500.12710/28530 |
ISBN: | 978-9975-3544-2-4 |
Appears in Collections: | MedEspera 2024
|
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
|