DC Field | Value | Language |
dc.contributor.author | Caproş, Nicolae | |
dc.date.accessioned | 2020-06-04T07:39:18Z | |
dc.date.available | 2020-06-04T07:39:18Z | |
dc.date.issued | 2009 | |
dc.identifier.citation | CAPROŞ, Nicolae. Corecţia chirurgicală a diformităţilor scoliotice cu instrumentaţia Cotrell – Dubousset. In: Arta Medica. 2009, nr. 2(35), pp. 40-46. ISSN 1810-1852. | en_US |
dc.identifier.issn | 1810-1852 | |
dc.identifier.uri | http://repository.usmf.md/handle/20.500.12710/10190 | |
dc.description | Catedra Ortopedie, Traumatologie şi Chirurgie în campanie,
Universitatea de Stat de Medicină şi Farmacie „N.Testemiţanu” | en_US |
dc.description.abstract | Scopul studiului a constat în analiza rezultatelor tratamentului chirurgical la care au fost supuşi 68 de pacienţi cu diformităţi scoliotice vertebrale cu instrumentaţii de corecţie dorsală de tip Cotrell-Dubousset perfecţionate. Preoperator, unghiul diformităţii curburii primare în ortostatism a constituit în medie 61,3±2,7°. Unghiul diformităţii scoliotice a curburii compensatorii în poziţie ortostatică a fost egal cu 42,9±2,3°. Corecţia intraoperatorie obţinută a curburii primare a fost de 34,5±1,7°, în medie, iar a curburii compensatorii - de 23,7±1,5°. Păstrarea corecţiei la distanţă a curburii primare a fost de 40,2±2,2°, iar a curburii compensatorii - de 27,8±1,7°. Pierderea corecţiei curburii primare a fost de 5,02±0,6°, la distanţă de 4,7±0,4 ani în medie, iar a curburii compensatorii - de 4,4±0,5°. Rata complicaţiilor la bolnavii operaţi a fost de 3,5%. | en_US |
dc.description.abstract | The aim of the study was în analysing the surgical treatment results of 68 patients with vertebral scoliotic deformations with dorsal corections instruments perfected Cotrell-Dubousset type. The prime curbe diformity angle in orthosthatism was arevaged as 61,3 2,7°. The scoliotic diformity angle of the compensatory curbe in orthostatic position was 42,9 2,3°. The obtained inner surgical correction of the prime curbe was 34,5 1,7° and of compensatory curbe - 23,7 1,5°. The distant correction maintainance of the prime curbe was 40,2 2,2° and of compensatory curbe - 27,8±1,7°. The medium distant correction was of 4,7±0,4° of the prime curbe was 5,02±0,6° and of the compensatory curbe - 4,4±0,5°. The complication rate of the patients was 3,5%. | |
dc.language.iso | ro | en_US |
dc.publisher | Asociaţia chirurgilor “Nicolae Anestiadi” din Republica Moldova | en_US |
dc.subject.mesh | Scoliosis--physiopathology | en_US |
dc.subject.mesh | Scoliosis--diagnosis | en_US |
dc.subject.mesh | Scoliosis--surgery | en_US |
dc.subject.mesh | Spinal Diseases | en_US |
dc.subject.mesh | Spinal Curvatures | en_US |
dc.subject.mesh | Equipment and Supplies, Hospital | en_US |
dc.subject.mesh | Surgical Instruments | en_US |
dc.title | Corecţia chirurgicală a diformităţilor scoliotice cu instrumentaţia Cotrell – Dubousset | en_US |
dc.title.alternative | Surgical treatment in scoliotic deformations with Cotrell-Dubousset instrumentation | en_US |
dc.type | Article | en_US |
Appears in Collections: | Arta Medica Vol. 35 No 2, 2009
|