USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/10233
Full metadata record
DC FieldValueLanguage
dc.contributor.authorStoian, Dana
dc.contributor.authorCraciunescu, Mihaela
dc.contributor.authorCraina, Marius
dc.contributor.authorVarcus, Florian
dc.contributor.authorPantea, Stelian
dc.date.accessioned2020-06-04T17:50:52Z
dc.date.available2020-06-04T17:50:52Z
dc.date.issued2018
dc.identifier.citationSTOIAN, Dana, CRACIUNESCU, Mihaela, CRAINA, Marius, VARCUS, Florian, PANTEA, Stelian. Faux positifs résultats de l’élastographie en temps réel dans le diagnostic des lésions nodulaires thyroïdiennes = False positive results of real-time elastography in the diagnosis of thyroid nodal lesions. In: The Moldovan Medical Journal. 2018, vol. 61, RMI Congress Issue, p. 54. ISSN 2537-6381.
dc.identifier.issn2537-6381
dc.identifier.issn2537-6373
dc.identifier.urihttp://moldmedjournal.md/wp-content/uploads/2018/05/The-Moldovan-Medical-Journal-vol-61-mai.pdf
dc.identifier.urihttp://repository.usmf.md/handle/20.500.12710/10233
dc.descriptionVictor Babes University of Medicine and Pharmacy, Timisoara, Romania, The IVth Congress of Radiology and Medical Imaging of the Republic of Moldova with international participation, Chisinau, May 31 – June 2, 2018en_US
dc.description.abstractIntroduction: L’élastographie en temps réel est une méthode de diagnostic qui ajoute de la qualité dans le diagnostic des lésions nodulaires thyroïdiennes. La méta-analyse actuelle suggère une bonne performance diagnostique avec une spécificité générale de 80% et une sensibilité générale de 85%. La présente étude est une analyse rétrospective des causes les plus fréquentes de faux negatifs et faux positifs résultats rencontrés dans l’échographie thyroïdienne. Matériel et méthodes: Nous avons analysé 433 des lésions nodulaires, opérés et évaluées par l’échographie de la thyroïde classique et l’élastographie, avec la même sonde linéaire, multifréquence, Hitachi Preirus machine, Hitachi Inc., Japon. Les résultats de l’échographie n’ont pas été communiqués au pathologiste. Une analyse rétrospective des résultats a été réalisée. Résultats: Nous avons évalué 433 cas avec des nodules avec un volume moyen de 2,14 ml (allant de 0,78 ml à 10,45 ml). 134/433 cas ont été identifiés avec un cancer de la thyroïde, 251/434 étant bénignes. La sensibilité de l’élastographie était de 82,02%, la spécificité de 83,94%, la précision de 83,37%. Nous avons observé 48 cas de lésions bénignes, identifiées par l’élastographie comme des lésions suspectes – 23/48 lésions avec de cellules Hürthle, sans maladies vasculaires, 8/48 lésions prolifératives potentiellement incertaines, 5/48 prolifération folliculaire, 8/48 thyroïdite myxomateuse / granulomateuse et 12/48 cas de maladie thyroïdienne auto-immune. Nous avons également noté 24 résultats faussement négatifs: 19/24T microcarcinomes papillaires, 5/25 carcinomes folliculaires. Être mentionné que les microcarcinomes qui ont été observés dans les nodules, ont de diamètres supérieurs à 3,5 cm. Conclusions: Les proliférations de cellules Hürthle et les microcarcinomes papillaires sont les conditions pour faux diagnostic le plus fréquent chez l’élastographie de la thyroïde.en_US
dc.description.abstractIntroduction: Real-time elastography is an imaging method that adds quality to the diagnosis of nodular thyroid lesions. Meta-analysis data suggest a good diagnostic performance with an overall specificity of 80% and sensitivity of 85%. The present study is a retrospective analysis of the most common causes of false negative and false positive results encountered in thyroid ultrasound. Material and methods: We analyzed 433 nodular lesions, operated and evaluated by classical thyroid ultrasound and elastography, using a linear probe on a Hitachi Preirus machine, Hitachi Inc., Japan: The results of the ultrasound were not communicated to the pathologist. A retrospective analysis of the results was performed. Results: We evaluated 433 thyroid nodules with an average volume of 2.14 ml (ranging from 0.78 ml to 10.45 ml). 134/433 cases were identified with thyroid cancer and 251/434 were identified as benign lesions. The sensitivity of the elastography was 82.02%, the specificity – 83.94%, the accuracy being 83.37%. We observed 48 cases of benign lesions, identified by elastography as suspicious lesions : 23/48 – lesions with Hürthle cells, without vascular diseases, 8/48 – proliferative lesions potentially uncertain, 5/48 – follicular proliferation, 8/48 – myxomatous / granulomatous thyroiditis and 12/48 cases of autoimmune thyroid disease. We also noted 24 false negative results: 19 / 24 – papillary microcarcinomas, 5/25 – follicular carcinomas. Of note is that microcarcinomas that have been observed in nodules, had > 3.5 cm in diameter. Conclusions: Hurtle cell proliferations and papillary microcarcinomas are the most common misdiagnosed conditions in thyroid elastography.
dc.publisherThe Scientific Medical Association of the Republic of Moldovaen_US
dc.relation.ispartofThe Moldovan Medical Journal: The IVth Congress of Radiology and Medical Imaging of the Republic of Moldova with international participation, Chisinau, May 31 – June 2, 2018
dc.subjectClassical thyroid ultrasound and elastographyen_US
dc.subjectNodal thyroid lesionsen_US
dc.subject.meshElasticity imaging techniques - methodsen_US
dc.subject.meshThyroid nodule - diagnostic imagingen_US
dc.subject.meshUltrasonography - methodsen_US
dc.titleFaux positifs résultats de l’élastographie en temps réel dans le diagnostic des lésions nodulaires thyroïdiennesen_US
dc.title.alternativeFalse positive results of real-time elastography in the diagnosis of thyroid nodal lesionsen_US
dc.typeArticleen_US
Appears in Collections:The Moldovan Medical Journal, Vol. 61, May 2018 RMI Congress Issue

Files in This Item:
File Description SizeFormat 
Faux_positifs_resultats_de_l_elastographie_en_temps_reel_dans_le_diagnostic_des_lesions.pdf54.99 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback