USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/13664
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSuman, S.-
dc.contributor.authorFruntașu, N.-
dc.contributor.authorSuman, A.-
dc.date.accessioned2020-12-06T19:32:06Z-
dc.date.available2020-12-06T19:32:06Z-
dc.date.issued2015-10-
dc.identifier.isbn978-9975-57-194-4-
dc.identifier.urihttp://repository.usmf.md/handle/20.500.12710/13664-
dc.descriptionCatedra de anatomie topografică și chirurgie operatorie, Laboratorul de Chirurgie Hepato-Bilio-Pancreatică, Catedra de chirurgie nr. 1 „N. Anestiadi”, Universitatea de Stat de Medicină şi Farmacie „Nicolae Testemiţanu”, Chişinău, Republica Moldova, Conferința Ştiinţifică Internaţională ”Probleme actuale ale morfologiei” dedicată celor 70 de ani de la fondarea Universității de Stat de Medicină și Farmacie „Nicolae Testemiţanu”, Chişinău, 15-16 octombrie 2015en_US
dc.description.abstractAbstract Background. The organs of human body analysed from the viewpoint of security of biological materials have their own biomechanical capacities. Thus, both the daily practice and practical medicine should take into account this fact. The values of physical and mechanical parameters of organs and tissues directly show the content and condition of connective tissue and its functions. As to determining the safety of biological material, the human duodenum, as well as the pylorus are at an incipient phase, which, presently, cannot be told about other anatomical formations. Material and methods. The walls of components of the human duodenum and pylorus have been studied. The material was sampled from 90 persons of both sexes, aged between 22 and 89 years old, whose organs of abdominal cavity were healthy. As many as 540 samples cut longitudinally and transversally and ring-shaped from the anterior wall of duodenum were examined. The values of indicators: breaking point, maximal relative expanding and coefficient of rigidity were set. Results. The values of the above-mentioned parameters were established. Data in figures are presented as tables and also provided with text data. The ring-shaped samples, regardless of their genesis, distinguish by a more increased breaking point against the lamellar samples. Both the maximal relative expanding and Young module vary within more restricted limits compared to breakout force and breaking point of samples. Conclusions. The analysis of breaking and deforming properties of pylorus and wall of components of duodenum in human allowed setting the values of main tensometric indicators (breaking point, maximal relative expanding, coefficient of rigidity) depending on the form of samples (lamellar, ring-shaped), portion of duodenum and direction of action of mechanical force (longitudinally, transversally).en_US
dc.language.isoroen_US
dc.publisherProbleme actuale ale morfologiei: Materialele Conferinţei ştiinţifice internaţionaleen_US
dc.subjectdeforming propertiesen_US
dc.subjectbiomechanical capacitiesen_US
dc.subjectbiological materialen_US
dc.titleProprietățile biomecanice ale pereților duodenului la omen_US
dc.title.alternativeBiomechanical properties of human duodenal wallsen_US
dc.typeArticleen_US
Appears in Collections:PROBLEME ACTUALE ALE MORFOLOGIEI 2015

Files in This Item:
File Description SizeFormat 
PROPRIETATILE_BIOMECANICE_ALE_PERETILOR_DUODENULUI_LA_OM.pdf132.91 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback