USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/21178
Full metadata record
DC FieldValueLanguage
dc.contributor.authorChaimov, Eden-
dc.date.accessioned2022-06-16T10:34:44Z-
dc.date.available2022-06-16T10:34:44Z-
dc.date.issued2022-
dc.identifier.citationCHAIMOV, Eden. Fit of screw - retained fixed partial denture in partial edentulism. In: MedEspera: the 9th International Medical Congress for Students and Young Doctors: abstract book. Chișinău: S. n., 2022, p. 352.en_US
dc.identifier.urihttps://medespera.asr.md/en/books-
dc.identifier.urihttp://repository.usmf.md/handle/20.500.12710/21178-
dc.description.abstractIntroduction. There are many ways to treat partially edentulous patients. In the last few decades, dental implants have become a valuable option for prosthodontic rehabilitation. The use of endosseous dental implants to replace natural teeth lost to periodontal disease, trauma, or complication of dental caries has become a predictable form of prosthetic treatment. A lot of research studies have demonstrated that implant prostheses represent a predictable and successful restorative solution for these cases. Passive fit of an implant framework is one of the mechanical parameters expected to influence the longevity of an implant prosthesis. Aim of study. To review the published literature for investigating the accuracy of fit of screw-retained fixed partial denture fabricated using different methods of manufacturing. Methods and materials. A comprehensive electronic search was performed through PubMed (MEDLINE). The following keywords were combined: “fixed prosthesis”, “implant,” “framework,” “fit,” “accuracy,” “fitting surface,” “bridge,” and “screw - retained. Results. A total of 30 articles were considered for review. After article selection, the relevant information from each article was extracted. From the selected studies, several implant framework fabrication methods were identified: conventional casting of metal alloys; sectioning and reconnection through soldering (the sectioned framework is indexed and reconnected with fused solder), CAD/ CAM, which involves fabricating the implant framework by means of computer numeric controlled milling; spark erosion, used to refine the fitting surface of the framework and framework bonding to a prefabricated abutment cylinder, where the framework body is constructed with space to accommodate a prefabricated cylinder and resin bonding is used to attach the framework body to the cylinders Conclusion. No method of manufacturing is ideal for fabrication of screw-retained fixed implant frameworks in all aspects. Casting of metal alloys generally does not provide an acceptable implant framework fit unless additional treatment is performed. The benefit of soldering is unclear and perhaps replaced by laser welding. Spark erosion, CAD/CAM, and framework bonding to prefabricated cylinders have great potential to overcome significant inaccuracies produced by the fabrication procedure and provide implant frameworks with excellent fit. CAD/CAM provides better results.en_US
dc.language.isoenen_US
dc.publisherNicolae Testemitanu State University of Medicine and Pharmacy of the Republic of Moldova, Association of Medical Students and Residents een_US
dc.relation.ispartofMedEspera: The 9th International Medical Congress for Students and Young Doctors, May 12-14, 2022, Chisinau, Republic of Moldovaen_US
dc.titleFit of screw - retained fixed partial denture in partial edentulismen_US
dc.typeOtheren_US
Appears in Collections:MedEspera 2022

Files in This Item:
File Description SizeFormat 
Fit_of_screw_retained_fixed_partial_denture_in_partial_edentulism.pdf218.96 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback