USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/21534
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRusu, Vasile-
dc.contributor.authorOineagra, Vasile-
dc.contributor.authorOineagra, Vadim-
dc.contributor.authorRusu, Andrei-
dc.date.accessioned2022-07-12T07:08:26Z-
dc.date.available2022-07-12T07:08:26Z-
dc.date.issued2019-
dc.identifier.citationRUSU, Vasile, OINEAGRA, Vasile, OINEAGRA, Vadim, RUSU, Andrei. Aspecte clinice şi tehnice în tratamentul edentaţiei unidentare prin proteze implanto-purtate = Clinical and technical aspects in the treatment of partial edentation by implant. In: Medicina stomatologică = Journal of Stomatological Medicine. 2019, vol. 3(52), pp. 83-90. ISSN 1857-1328.en_US
dc.identifier.issn1857-1328-
dc.identifier.urihttps://www.asrm.md/ro/arhiva/revista-medicina-stomatologica-nr-3-2019-
dc.identifier.urihttp://repository.usmf.md/handle/20.500.12710/21534-
dc.description.abstractRezumat. Este prezentat analiza a trei metode de fixare a protezelor fixe unidentare implantopuratate unde am analizat cantitatea de ciment ce refluează în afara liniei de conexiune dintre abutmentul standart, abutment individual hybrid şi înşurubare, cu ajutorul metodei fotometrice. Acest studiu s-a efectuat pe cadru tripodic, la aceiaşi distanţă, unghi, parametrii, lumină şi folosind aceiaşi cantitate de ciment în fiecare coroană. Calibrarea s-a efectuat cu ajutorul unui analog calibrat. În rezultatul cercetării am observat că cantitatea de ciment ce refluează în afara liniei de conexiune dintre abutmentul standart, abutment individual hybrid şi coroana este diferit.en_US
dc.description.abstractSummary. Was made the analysis of three methods of prosthesis fixing on the implants, where we analyzed the amount of cement reflecting off the connection line between the standard abutment, individual hybrid abutment and screwing, using the photometric method. This study was performed on a tripod frame, at the same distance, angle, parameters, light and using the same amount of cement in each crown. Calibration was performed using a calibrated analog. As a result of the research we noticed that the amount of cement reflecting off the connection line between the standard abutment, individual hybrid abutment and the crown is different.en_US
dc.publisherAsociaţia Stomatologilor din Republica Moldova, Universitatea de Stat de Medicină și Farmacie „Nicolae Testemiţanu“en_US
dc.relation.ispartofMedicina Stomatologicăen_US
dc.subjectstandard abutmenten_US
dc.subjectindividual hybriden_US
dc.subjectscrewen_US
dc.titleAspecte clinice şi tehnice în tratamentul edentaţiei unidentare prin proteze implanto-purtateen_US
dc.title.alternativeClinical and technical aspects in the treatment of partial edentation by implanten_US
dc.typeArticleen_US
Appears in Collections:Medicina Stomatologică 2019/ Nr. 3(52)

Files in This Item:
File Description SizeFormat 
8_ASPECTE_CLINICE_SI_TEHNICE_IN_p.83_90.pdf319.92 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback