DC Field | Value | Language |
dc.contributor.author | Gumeniuc, Aureliu | - |
dc.date.accessioned | 2022-08-30T07:47:39Z | - |
dc.date.available | 2022-08-30T07:47:39Z | - |
dc.date.issued | 2014 | - |
dc.identifier.citation | GUMENIUC, Aureliu. Densitometria oaselor maxilare: studiu retrospectiv de analogare a densităţii optice relativă a clișeelor OPG cu datele periotestometriei. In: Medicina stomatologică. 2014, Nr. 3(32), pp. 84-87. ISSN 1857-1328. | en_US |
dc.identifier.issn | 1857-1328 | - |
dc.identifier.uri | https://www.asrm.md/ro/arhiva/nr-3-33-2014c | - |
dc.identifier.uri | http://repository.usmf.md/handle/20.500.12710/21703 | - |
dc.description.abstract | Rezumat.
Studiul densitometric a fost efectuat în baza a 196 de clișee OPG realizate preimplantar. Au fost examinate 327 de zone ale maxilarelor, respectiv
pentru aplicarea a 572 implante dentare one piece. Datele obţinute au fost
prelucrate statistic prin corelare cu rezultatele primite în studiile anterioare referitor la valorile Periotest® a stabilităţii primare a implantelor imediat după inserarea lor și aprecierea densităţii oaselor maxilarelor în timpul
formării neoalveolelor. Rezultatele obţinute au demonstrat o corelaţie inversă puternică între indicii de densitometrie obţinuţi atât faţă de valorile
Periotest® a stabilităţii primare (r=-0,74, p<0,001), cât și a densităţii oaselor
maxilarelor apreciate intraoperator (r=-0,71, p<0,001). | en_US |
dc.description.abstract | Summary.
The study of bone density was based on 196 orthopantomograms made
before implant placement. 327 maxillary zones had been examined for the
insertion of 572 one-piece dental implants. The received data had been statistically processed by correlating the previous results of Periotest® values
of the primary stability with the bone density assessment during implant
insertion procedures. The obtained results have shown a strong inverse correlation between the obtained densitometry values both with the Periotest®
values of primary stability (r=-0,74, p<0,001), as well as with the bone density appreciated during surgery(r=-0,71, p<0,001). | en_US |
dc.language.iso | ro | en_US |
dc.publisher | Asociaţia Stomatologilor din Republica Moldova, Universitatea de Stat de Medicină și Farmacie „Nicolae Testemiţanu“ | en_US |
dc.relation.ispartof | Medicina Stomatologică | en_US |
dc.subject | densitometry | en_US |
dc.subject | one-piece dental implant | en_US |
dc.subject | Periotest® values | en_US |
dc.subject | primary stability | en_US |
dc.title | Densitometria oaselor maxilare: studiu retrospectiv de analogare a densităţii optice relativă a clișeelor OPG cu datele periotestometriei | en_US |
dc.type | Article | en_US |
Appears in Collections: | Medicina Stomatologică 2014/ Nr. 3(32)
|