USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/23413
Full metadata record
DC FieldValueLanguage
dc.contributor.authorTuciac, Carolina
dc.contributor.authorBaban, Lilia
dc.date.accessioned2022-12-20T08:06:00Z
dc.date.available2022-12-20T08:06:00Z
dc.date.issued2010
dc.identifier.citationTUCIAC, Carolina, BABAN, Lilia. Rolul tomografiei computerizate cu rază conică în stomatologie. In: Medicina stomatologică. 2010, Nr. 1(14), pp. 7-10. ISBN 978-9975-52-006-5.en_US
dc.identifier.isbn978-9975-52-006-5 4
dc.identifier.urihttps://www.asrm.md/ro/arhiva/nr-1-14-2010
dc.identifier.urihttp://repository.usmf.md/handle/20.500.12710/23413
dc.description.abstractRezumat. CT CB este o nouă metodă imagistică de performanţă înaltă pe larg folosită în stomatologie care permite un diagnostic precoce şi complet al diferitor maladii oromaxilofaciale. Principiul de lucru a tomografului Gendex CB-500 este cone-beam, fascicolul conic al razei roentghen care este amplificată şi înregistrată de către un sensor de lumină foarte sensibil cu rezoluţie înaltă. Distanţa lineară minimă de 0,2 mm o primim tridimensional: sagital, coronal, axial, pe o suprafaţă maximă de diafragmare de 8 cm, micşorînd doza de iradiere comparativ cu CT spiralate existente.en_US
dc.description.abstractSummary. CT CB is a new high-performance imagery method widely used in dentistry that allows an early and complete diagnosis of different oromaxilofacial diseases. Working principle of the tomograph Gendex CB-500 is cone-beam, the conical beam of roentghen ray which is amplified and recorded by a very sensitive light sensor with high resolution. The minimum linear distance of 0,2 mm is received in a three-dimensional mode: sagittal, coronal, axial, on a maximum diaphragm area of 8 cm, reducing radiation dose comparatively with existing spiral CT.en_US
dc.language.isoroen_US
dc.publisherAsociaţia Stomatologilor din Republica Moldova, Universitatea de Stat de Medicină și Farmacie „Nicolae Testemiţanu“en_US
dc.relation.ispartofMedicina Stomatologicăen_US
dc.titleRolul tomografiei computerizate cu rază conică în stomatologieen_US
dc.title.alternativeRole of computed tomography range tapered dental
dc.typeArticleen_US
Appears in Collections:Medicina Stomatologică 2010/ Nr. 1(14)

Files in This Item:
File Description SizeFormat 
Rolul_tomografieicomputerizate_cu_raza_conica.pdf1.54 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback