USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/24057
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBilgehan, Sezgin Asena-
dc.date.accessioned2023-04-06T07:06:25Z-
dc.date.available2023-04-06T07:06:25Z-
dc.date.issued2021-
dc.identifier.citationBILGEHAN, Sezgin Asena. The flap thickness outcomes with new dual femtosecond laser platform. In: 19th Black Sea Ophthalmological Society Congress, September 24-26, 2021, Chisinau, Republic of Moldova: abstract book, p. 26.en_US
dc.identifier.urihttps://aom.md/wp-content/uploads/2021/10/ABSTRACT-BOOK_web.pdf-
dc.identifier.urihttp://repository.usmf.md/handle/20.500.12710/24057-
dc.description.abstractPurpose: To evaluate flap thickness in femtosecond (FS) laser assisted LASIK operation for myopia performed with new LenSx dual platform using curved interface. Materials and methods: Fifty eyes of 26 patients (mean±SD age: 26.9±8.1 years, 53.8% were females) with myopia or myopic astigmatism operated with FS laser-assisted LASIK were evaluated in this study. Data on patient demographics, preoperative and postoperative keratometric and aberrometric parameters and flap thickness outcome including mean central flap thickness (MCFT), mean total flap thickness (MTFT), intra-FT range and flap thickness homogeneity (FTH) were recorded. Results: Flap thickness assessment revealed median values for MCFT to be 123 µm (range, 109 to 134), while MTFT was 123 µm (range, 109 to 133.7), Intra-FT range was 4.0 µm (ranged, 1 to 6) and FTH was -2 µm (range, -6 to 2). Overall flap thickness was thicker than planned by +3.0 μm (minimum, 109.0 μm with a −11.0 μm average difference and maximum, 133.7 μm with a +13.7 μm difference) with an average thickness standard deviation of 6.6 μm. Conclusions: In conclusion, our findings related to FS laser assisted LASIK surgery for myopia with new LenSx dual platform using curved interface revealed favorable corneal flap thickness outcome in terms of closeness of flap thickness to the intended value and low intra-flap range. Thus, our findings emphasize the likelihood of planning and producing more successful LASIK outcomes in terms of consistency and predictability of corneal flap thickness with use of new LenSx dual platform.en_US
dc.language.isoenen_US
dc.publisherBlack Sea Ophthalmological Society, Ophthalmological Association from Moldova, Nicolae Testemitanu State University of Medicine and Pharmacy of the Republic of Moldovaen_US
dc.relation.ispartof19th Black Sea Ophthalmological Society Congress, September 24-26, 2021 Chisinau, Republic of Moldovaen_US
dc.titleThe flap thickness outcomes with new dual femtosecond laser platformen_US
dc.typeOtheren_US
Appears in Collections:19th Black Sea Ophthalmological Society Congress, September 24-26, 2021 Chisinau, Republic of Moldova

Files in This Item:
File Description SizeFormat 
THE_FLAP_THICKNESS_OUTCOMES_WITH_NEW_DUAL_FEMTOSECOND_LASER_PLATFORM.pdf223.28 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback