DC Field | Value | Language |
dc.contributor.author | Arion, Marian | |
dc.contributor.author | Pleșcan, Tatiana | |
dc.date.accessioned | 2019-06-24T20:03:01Z | |
dc.date.available | 2019-06-24T20:03:01Z | |
dc.date.issued | 2015 | |
dc.identifier.citation | ARION, Marian, PLEȘCAN, Tatiana. Tehnica proiecţiei de intensitate maximă în evaluarea anevrismelor poligonului Willis: studiu prospectiv, pe serie de cazuri = Maximum intensity projection technique in evaluation of Willis polygon aneurysms: a prospective, case series study. In: Revista de Ştiinţe ale Sănătăţii din Moldova. 2015, vol. 6(4), pp. 55-70. ISSN 2345-1467. | |
dc.identifier.issn | 2345-1467 | |
dc.identifier.uri | https://stiinta.usmf.md/sites/default/files/2018-09/MJHS%20nr.4%20_2015.pdf | |
dc.identifier.uri | http://repository.usmf.md/handle/20.500.12710/2474 | |
dc.description.abstract | Introducere. În ultimele decenii, metodele de postprocesare au crescut proporţional în importanţă, inclusiv, în stabilirea diagnosticului primar. Cu toate acestea, existenţa numeroaselor tehnici de reformatare a imaginilor angiografiei cu scanare computer tomografică necesită estimarea influenţei lor asupra calităţii finale a examinării. Este necesară determinarea avantajelor și limitărilor diferitor tehnici de reformatare a imaginii AST. Material și metode. Incluși 140 de pacienţi consecutivi, în vârstă de 19-79 de ani, cu anevrisme cerebrale ale poligonului Willis. În vederea stabilirii diagnosticului și în scopul determinării oportunităţii indicaţiei pentru tratament neurochirurgical, pacienţii au fost investigaţi prin computer tomografie cerebrală nativă, angiografie cerebrală cu scanare computer tomografică (imaginile primare axiale) și următoarele procedee de reconstrucţie a angiografiei computer tomografică: proiecţie de intensitate maximă (PIM), reconfigurare volumetrică tridimensională (RV-3D). Rezultate. Tehnica PIM a constatat anevrism vizibil în 99,3% de cazuri și anevrism parţial vizibil în 0,7% cazuri. Marea majoritate a anevrismelor erau saculare (96,5%). Hemoragia intracraniană, cauzată de ruperea anevrismului, a fost depistată în 75,0% din cazuri, vazospasmul – în 59,3% din cazuri, calcificate parietale – în 3,6% din cazuri, artefacte tip „efect de volum parţial” – în 82,9% din cazuri, artefacte de la clipsul metalic – în 69,3% din cazuri și trombi în anevrism – în 6,4% din cazuri. În cadrul reconstrucţiei PIM, contactul osanevrism nu se vizualiza în 12,8% cazuri, se vizualiza slab – în 28,2% din cazuri și bine – în 59,0 din cazuri. Relaţia cu sinusul cavernos nu se vizualiza în 16,6% din cazuri, se vizualiza slab în 50% din cazuri, bine – în 33,4% din cazuri. Concluzii. Imaginile proiecţiei de intensitate maximă trebuie să fie tehnica de reconstrucţie primară și necesită a fi inclusă în protocolul de analiză standard a angiografiei prin tomografie computerizată pentru estimarea arterelor cervicocraniene. | ro |
dc.description.abstract | Introduction. In the past few decades, methods of post processing have evolved proportionally, their role in stabilizing the primary diagnosis as well. Nevertheless, existence of many techniques of image reconfiguration makes it necessary to estimate their influence on final examination results. It is mandatory to determine the advantages and limitations of different techniques of CTA reconfiguration. Material and methods. One hundred and forty consecutive patients were included, aged 19-79, diagnosed with aneurysms of Willis polygon. In order to determine the diagnose and the possible following surgical treatment, patients were investigated through methods of native cerebral computer tomography, cerebral angiography with CT scanning (CTA, primary axial images) and the following methods of reconstruction of CTAs: maximum intensity projection (MIP) and tridimensional volumetric reconfiguration (3D-VR). Results. MIP technique showed visible aneurysm in 99.3% of the cases and partial visible aneurysm in 0.7% of the cases. The big majority of the aneurysms were saccular (96.5%). Intracranial bleeding caused by aneurysm rupture was found in 75.0% of the cases, vasospasm – in 59.3% of the cases, parietal calcification – in 3.6% of the cases, “partial volume effect” artifacts – in 82.9% of the cases, metal clip artifact – in 69.3% of the cases and aneurysm cloths – in 6.4% of the cases. During MIP reconstruction, aneurysm-bone contact could not be visualized in 12.8% of the cases, was poorly visualized in 28.2% of the cases and was well visualized in 59.0% of the cases. The relation with the cavernous sinus could not be appreciated in 16.6% of the cases, was poorly visualized in 50% of the cases and was well visualized in 33.4% of the cases. Conclusions. Images of maximum intensity must be the primary technique for reconstruction and must be included in the protocol of standard analysis of CTA in order to estimate the cervical and cranial arteries. | en |
dc.publisher | Instituţia Publică Universitatea de Stat de Medicină şi Farmacie „Nicolae Testemiţanu” din Republica Moldova | en_US |
dc.relation.ispartof | Revista de Științe ale Sănătății din Moldova = Moldovan Journal of Health Sciences | |
dc.subject | maximum intensity projection | en_US |
dc.subject | Willis polygon | |
dc.subject | subarachnoid hemorrhage | |
dc.subject | cerebral aneurysm | |
dc.subject | computed tomography angiography | |
dc.subject.mesh | Circle of Willis--pathology | en_US |
dc.subject.mesh | Intracranial Aneurysm--diagnosis | en_US |
dc.subject.mesh | Computed Tomography Angiography--methods | en_US |
dc.subject.mesh | Image Processing, Computer-Assisted | en_US |
dc.subject.mesh | Multimodal Imaging | en_US |
dc.subject.mesh | Case Reports | en_US |
dc.title | Tehnica proiecţiei de intensitate maximă în evaluarea anevrismelor poligonului Willis: studiu prospectiv, pe serie de cazuri | ro |
dc.title.alternative | Maximum intensity projection technique in evaluation of Willis polygon aneurysms: a prospective, case series study | en_US |
dc.type | Article | en_US |
Appears in Collections: | Revista de Științe ale Sănătății din Moldova : Moldovan Journal of Health Sciences 2015 Vol. 6(4)
|