USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/24946
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMîrzac, Viorica
dc.date.accessioned2022-12-15T12:50:28Z
dc.date.accessioned2023-06-19T14:09:35Z
dc.date.available2022-12-15T12:50:28Z
dc.date.available2023-06-19T14:09:35Z
dc.date.issued2022
dc.identifier.citationMÎRZAC, Viorica. Influența oxigenului asupra procesului de coroziune a cuprului = Effect of oxygen on copper corrosion. In: Revista de Ştiinţe ale Sănătăţii din Moldova. 2022, vol. 29(3), anexa 1, p. 497. ISSN 2345-1467.en_US
dc.identifier.issn2345-1467
dc.identifier.urihttps://conferinta.usmf.md/wp-content/uploads/MJHS_29_3_2022_anexa_.pdf
dc.identifier.urihttp://repository.usmf.md/handle/20.500.12710/24946
dc.description.abstractIntroducere. Cunoașterea proprietăților corozive ale suprafețelor este importantă în contextul selectării materialelor în dependență de caracteristicile lor. Modificarea parametrilor metalului în timp sau caracterizarea rezultatului coroziunii permit determinarea vitezei de coroziune și a proprietăților corozive. Scopul lucrării. Cercetarea influenței oxigenului asupra procesului de coroziune a cuprului în electroliți corozivi. Material și Metode. A fost măsurat potențialul în circuitul deschis (OCP) al probei din cupru cu suprafața 2,5 cm 2 vs. Ag/AgCl, la temperatura camerei cu potențiostatul PARSTAT 2273 (Princeton Applied Research), în electrolitul pirofosfat (g L -1 : CuSO 4·5H 2O - 12,5; Na 4P 2O 7·5H 2O - 100; pH = 8) și în soluția 0,5M de Na 2SO 4 ca mediu coroziv. Rezultate. S-a observat micșorarea OCP a cuprului în electrolitul pirofosfat de la -0,209 V (în absența argonului) până la -0,218 V în prezența argonului (timp de 30 minute înainte și în timpul măsurării). În soluția 0,5M de sulfat de sodiu s-a constatat deplasarea OCP a cuprului spre valori mai negative în prezența argonului -0,027 V în comparație cu -0,006 V. Prin urmare, prezența argonului inert a condus la inhibarea procesului de coroziune a cuprului. S-a înregistrat o variație mai mare a OCP a cuprului în soluția 0,5M de sulfat de sodiu (0,021 V) în comparație cu electroli tul pirofosfat (0,009 V). Concluzii. Micșorarea concentrației oxigenului în sistem conduce la scăderea vitezei procesului de reducere a oxigenului dizolvat. Prin urmare, OCP se deplasează spre valori catodice și viteza de coroziune a cuprului se micșorează.en_US
dc.description.abstractBackground. Knowledge of the corrosive properties of surfaces is important in the context of selecting materials according to their characteristics. Changing the parameters of the metal over time or characterizing the corrosion result allows the determination of the corrosion rate and corrosive properties. Objective of the study. Studying the effect of oxygen on the corrosion of copper in corrosive electrolytes. Material and Methods. The open circuit potential (OCP) of the 2.5 cm 2 copper sample is measured vs. Ag/AgCl, at room temperature with PARSTAT 2273 potentiostat (Princeton Applied Research), in the pyrophosphate electrolyte (g L -1 : CuSO 4·5H 2O – 12.5; Na 4P 2O 7·5H 2O - 100; pH = 8) and in 0.5M Na 2SO 4 solution as a corrosive medium. Results. The obtained data has shown copper OCP decrease in the pyrophosphate electrolyte from -0.209 V (in the absence of argon) to -0.218 V in the presence of argon (30 minutes prior to and during the measurement). In the 0.5M sodium sulphate solution, the copper OCP has dropped to more negative values in the presence of argon -0.027 V compared to -0.006 V. Thus, inert argon led to inhibition of the copper corrosion. The variation of copper OCP in the 0.5M sodium sulphate solution was more pronounced (0.021 V) than in the pyrophosphate electrolyte (0.009 V). Conclusion. Decreasing the concentration of oxygen in the system decreases the rate of the reduction process of dissolved oxygen. Therefore, the OCP moves to cathodic values and the corrosion rate of copper decreases.en_US
dc.publisherInstituţia Publică Universitatea de Stat de Medicină şi Farmacie „Nicolae Testemiţanu” din Republica Moldovaen_US
dc.relation.ispartofRevista de Științe ale Sănătății din Moldova: Moldovan Journal of Health Sciences: Conferinţa ştiinţifică anuală "Cercetarea în biomedicină și sănătate: calitate, excelență și performanță", 19-21 octombrie 2022, Chișinău, Republica Moldovaen_US
dc.subjectcopper corrosionen_US
dc.subjectcorrosion inhibitionen_US
dc.titleInfluența oxigenului asupra procesului de coroziune a cupruluien_US
dc.title.alternativeEffect of oxygen on copper corrosionen_US
dc.typeAbstracten_US
Appears in Collections:Revista de Științe ale Sănătății din Moldova : Moldovan Journal of Health Sciences 2022 nr. 3(29) Anexa 1

Files in This Item:
File Description SizeFormat 
MJHS_29_3_2022_A_p497.pdf154.64 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback