DC Field | Value | Language |
dc.contributor.author | Bernic, Vladimir | - |
dc.contributor.author | Țapu, Livia | - |
dc.contributor.author | Ilie, Anton | - |
dc.contributor.author | Bucata, Elena | - |
dc.contributor.author | Macari, Doina | - |
dc.contributor.author | Ferdohleb, Alina | - |
dc.date.accessioned | 2023-10-26T18:56:06Z | - |
dc.date.available | 2023-10-26T18:56:06Z | - |
dc.date.issued | 2023 | - |
dc.identifier.citation | BERNIC, Vladimir, ȚAPU, Livia, ILIE, Anton et al. Managementul preparării probelor din ape reziduale - intervenție strategică de prevenire a diseminării antibioticorezistenței = Management of preparation of waste water samples - strategic intervention to prevent the dissemination of antibioticoresistance. In: Revista de Ştiinţe ale Sănătăţii din Moldova = Moldovan Journal of Health Sciences. 2023, vol. 10(3), anexa 1, p. 119. ISSN 2345-1467. | en_US |
dc.identifier.issn | 2345-1467 | - |
dc.identifier.uri | https://conferinta.usmf.md/wp-content/uploads/Culegerea-Rezumate-MJHS_10_3_2023_anexa1.pdf | - |
dc.identifier.uri | http://repository.usmf.md/handle/20.500.12710/25557 | - |
dc.description.abstract | Introducere. Zona Umedă Construită (ZUC) Orhei, la moment, prezintă cel mai mare sistem complex din Europa de
tratare a apelor reziduale. ZUC Orhei deservește aproximativ 26000 de locuitori, câteva instituții economice, publice,
inclusiv medico-sanitare. Mărimea și capacitatea ZUC Orhei,
necesită un management particular, în evaluarea calității
tratării apelor reziduale din punct de vedere microbiologic.
Scopul lucrării constă în prezentarea metodologiei prelevării și pregătirii probelor de ape reziduale pentru analize
moleculare în vederea eficientizării procesului de tratare a
apelor reziduale din ZUC, ca strategie de intervenție pentru
a preveni diseminarea rezistenței la antibiotice (RAM) în
apele de suprafață. Material și metode. Lucrarea se bazează pe protocolul de prelevare a apelor reziduale, elaborat în
cadrul proiectului PhageLand. Au fost descrise modalitatea
de prelevare și manipulare a probelor pentru analize moleculare (metagenomică). Rezultate. Punctele de colectare a
probelor au fost selectate urmând procesul tehnologic: apă
reziduală brută; 4 puncte de pe liniile platformei de stuf filtrant (RBF); 4 puncte de pe liniile platformei cu flux vertical (VF) și produsul final. Probele au fost colectate folosind
sticle sterile din borosilicat de 1l. Odată ajunse în laborator,
un volum de apă (250ml pentru efluenți și 50ml pentru apă
reziduală brută) a fost filtrat prin membrane cu ∅ porilor
de 0,2 µm folosind un dispozitiv de filtrare la vid (3 filtre/
probă). Filtrele au fost introduse în tuburi Eppendorf sterile de 2 ml și depozitate la (–20ºC) până la livrarea către
Universitatea din Varșovia pentru extracția ADN și analiza
metagenomică. Concluzii. Metodologia prezentată a permis
realizarea unei caracterizări a comunităților bacteriene, resistomului cu scopul eficientizării procesului de tratare a
apelor reziduale din ZUC Orhei. | en_US |
dc.description.abstract | Background. The Orhei Constructed Wetland (CW), now,
presents the largest complex system in Europe for wastewater treatment. Orhei CW serves about 26,000 inhabitants,
several economic, and public institutions, including medical
and sanitary ones. The size and capacity of Orhei CW require particular management, in assessing the quality of wastewater treatment, especially from a microbiological point
of view. Objective of the study is to present the methodology of sampling and preparation of wastewater samples for
molecular analysis in order to streamline the wastewater
treatment process in the CW, as an intervention strategy to
prevent the spread of antibiotic resistance (ARM) in surface waters. Material and methods. This paper is based on
the wastewater sampling protocol, developed within PhageLand project. The method of sampling and handling of
samples for molecular analysis (metagenomics) has been
described. Results. The collecting points of wastewater
samples were selected based on the technological process,
as follows: raw wastewater; 4 points from the lines of the
filter reed platform (RBF); 4 points from the lines of the vertical flow platform (VF) and the final product. Samples were
collected using sterile borosilicate bottles of 1L. Once in the
laboratory, a known volume of water (250ml for effluents
and 50ml for raw wastewater) was filtered through membranes with a pore ∅ of 0.2 µm using a vacuum filter device
(3 filters/sample). The filters were inserted into sterile 2 ml
Eppendorf tubes and stored at (– 20℃) until delivery to the
University of Warsaw for DNA extraction and metagenomic
analysis. Conclusion. The presented methodology allowed
us to carry out a characterization of bacterial communities and resistome to streamline the wastewater treatment
process in Orhei CW. | en_US |
dc.publisher | Instituţia Publică Universitatea de Stat de Medicină şi Farmacie „Nicolae Testemiţanu” din Republica Moldova | en_US |
dc.relation.ispartof | Revista de Științe ale Sănătății din Moldova: Moldovan Journal of Health Sciences: Conferinţa ştiinţifică anuală "Cercetarea în biomedicină și sănătate: calitate, excelență și performanță", 18-20 octombrie 2023, Chișinău, Republica Moldova | en_US |
dc.subject | waste-water | en_US |
dc.subject | Constructed Wetland | en_US |
dc.subject | PhageLand | en_US |
dc.subject | antibiotic resistance | en_US |
dc.title | Managementul preparării probelor din ape reziduale - intervenție strategică de prevenire a diseminării antibioticorezistenței | en_US |
dc.title.alternative | Management of preparation of waste water samples - strategic intervention to prevent the dissemination of antibioticoresistance | en_US |
dc.type | Other | en_US |
Appears in Collections: | Revista de Științe ale Sănătății din Moldova : Moldovan Journal of Health Sciences 2023 nr. 3(10) Anexa 1
|