USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/26319
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSpinei, I.-
dc.contributor.authorCasian, D.-
dc.contributor.authorCuliuc, V.-
dc.contributor.authorSmolnițchi, R.-
dc.contributor.authorIstrati, V.-
dc.date.accessioned2023-11-09T11:59:29Z-
dc.date.available2023-11-09T11:59:29Z-
dc.date.issued2023-
dc.identifier.citationSPINEI, I., CASIAN, D., CULIUC, V., SMOLNIȚCHI, R., ISTRATI, V. Corelații între caracteristica anatomică a leziunilor ocluziv-stenotice ale arterelor infrainghinale conform „GLASS” și severitatea clinică a ischemiei cornice = Correlation of anatomic characteristics of occlusive-stenotic lesions of infrainguinal arteries according to „GLASS” and clinical severity of chronic ischemia. In: Arta Medica. 2023, nr. 3(88), pp. 83-84. ISSN 1810-1852.en_US
dc.identifier.issn1810-1852-
dc.identifier.issn1810-1879-
dc.identifier.urihttps://artamedica.md/index.php/artamedica/issue/view/17/23-
dc.identifier.urihttp://repository.usmf.md/handle/20.500.12710/26319-
dc.description.abstractScopul lucrării. Clasificarea GLASS (Global Limb Anatomic Scoring System) a fost implementată recent pentru a determina pronosticul intervențiilor de revascularizare. Scopul studiului a fost studierea corelațiilor între caracteristica anatomică a leziunilor ocluziv-stenotice infrainghinale, descrise conform GLASS și severitatea ischemiei cronice (IC). Materiale și metode. Studiul a inclus 125 pacienți (141 membre) cu IC. GLASS a fost determinat în baza datelor DSA (digital subtraction angiography) și a inclus descrierea segmentului femuro-popliteal (FP), infrapopliteal (IP) și arcului plantar (P); stabilirea stadiului și calcularea scorului compozit (FP+IP+P). Severitatea IC a fost evaluată prin valorile indicelui gleznă-braț (IGB), PAT (pedal acceleration time) și clasificarea WIfI. Rezultate. Stadiul GLASS I a fost determinat în 16 (11,3%) cazuri, GLASS II – în 29 (20,5%) și GLASS III – în 96 (68%). Nu au existat diferențe semnificative între stadii referitor la vârsta și genul bolnavilor. Valorile IGB au fost semnificativ mai mici la pacienții cu GLASS III – 0,44±0,18 vs 0,52±0,16 în GLASS II și 0,58±0,12 în GLASS I (p<0,05). Respectiv, valorile PAT au fost veridic mai mari în stadiul GLASS III – 206±30 ms vs 168±26 ms în GLASS II și 140±14 ms în GLASS I (p<0,05). Scorul GLASS compozit a demonstrat corelație negativă moderată cu valorile IGB: rs = -0,37 (95%CI -0,51 – -0,21), p<0,0001. Vice versa, rata cazurilor cu stadiul WIfI 3-4 și valoarea scorului mediu WIfI nu s-au deosebit între GLASS I-III. Concluzii. Caracteristicile anatomice ale leziunilor ocluziv-stenotice, cuantificate conform GLASS, corelează cu severitatea ischemiei, însă nu influențează în mod direct riscul de amputație a membrului.en_US
dc.description.abstractAim of study. GLASS (Global Limb Anatomic Scoring System) classification was implemented recently aimed to predict the success of revascularization. The aim was evaluation of correlation between anatomic characteristics of infrainguinal occlusive-stenotic lesions, described by GLASS, and clinical severity of chronic ischemia (CI). Materials and methods. Study cohort included 125 patients (141 limbs) with CI. GLASS was determined basing on DSA (digital subtraction angiography) data and included description of femoral-popliteal (FP), infrapopliteal (IP) segments, plantar arch (P); determination of stage and calculation of composite score (FP+IP+P). Severity of CI was evaluated with ankle-brachial index (ABI), PAT (pedal acceleration time) and WIfI classification. Results. Stage GLASS I was determined in 16 (11,3%) cases, GLASS II – in 29 (20.5%) and GLASS III – in 96 (68%). There were no differences in age and gender of the patients between stages. ABI values were significantly lower in patients with GLASS III – 0.44±0.18 vs 0.52±0.16 in GLASS II and 0.58±0.12 in GLASS I (p<0.05). Similar, values of PAT were significantly higher in GLASS III – 206±30 ms vs 168±26 ms in GLASS II and 140±14 ms in GLASS I (p<0.05). GLASS composite score demonstrated moderate negative correlation with ABI values: rs = -0.37 (95%CI -0.51 – -0.21), p<0.0001. Vice versa, rate of limbs with WIfI stages 3-4 as well as values of mean WIfI score were similar in GLASS stages I-III. Conclusions. Anatomic characteristics of the occlusive-stenotic lesions, quantified according to GLASS, corelate with severity of ischemia, but not directly influence the risk of limb amputation.en_US
dc.publisherAsociaţia chirurgilor “Nicolae Anestiadi” din Republica Moldovaen_US
dc.relation.ispartofArta Medica: Al XIV-lea Congres al Asociației Chirurgilor „Nicolae Anestiadi” și al IV-lea Congres al Societății de endoscopie, chirurgie minim invazivă și ultrasonografie „V.M.Guțu” din Republica Moldova (cu participare internaţională), 21-23 septembrie 2023, Chișinău, Republica Moldovaen_US
dc.subjectchronic ischemiaen_US
dc.subjectWIfI classificationen_US
dc.subjectGLASS classificationen_US
dc.subjectankle-brachial indexen_US
dc.titleCorelații între caracteristica anatomică a leziunilor ocluziv-stenotice ale arterelor infrainghinale conform „GLASS” și severitatea clinică a ischemiei corniceen_US
dc.title.alternativeCorrelation of anatomic characteristics of occlusive-stenotic lesions of infrainguinal arteries according to „GLASS” and clinical severity of chronic ischemiaen_US
dc.typeOtheren_US
Appears in Collections:Arta Medica Nr. 3(88) 2023

Files in This Item:
File Description SizeFormat 
83_84_Spinei_Corelatii.pdf207.34 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback