DC Field | Value | Language |
dc.contributor.author | Guţu, S. | - |
dc.contributor.author | Gagauz, I. | - |
dc.contributor.author | Guzun, V. | - |
dc.date.accessioned | 2023-11-15T12:06:09Z | - |
dc.date.available | 2023-11-15T12:06:09Z | - |
dc.date.issued | 2023 | - |
dc.identifier.citation | GUŢU, S., GAGAUZ, I., GUZUN, V. Textilom abdominal versus poliuretanom: diferențe semnificative = Abdominal textiloma versus polyurethanoma: significant differences. In: Arta Medica. 2023, nr. 3(88), pp. 97-98. ISSN 1810-1852. | en_US |
dc.identifier.issn | 1810-1852 | - |
dc.identifier.issn | 1810-1879 | - |
dc.identifier.uri | https://artamedica.md/index.php/artamedica/issue/view/17/23 | - |
dc.identifier.uri | http://repository.usmf.md/handle/20.500.12710/26379 | - |
dc.description.abstract | Scopul lucrării. Reţinerea neintenţionată a unei matrice textile în cavitatea abdominală reprezintă una dintre cele mai grave și
cunoscute erori chirurgicale. Totodată, în ultimii ani, popularitatea terapiei plăgilor cu presiune negativă (TPPN) a crescut semnificativ.
Metoda a început să fie utilizată activ în infecţiile intraabdominale severe, ceea ce a dus la cazuri de uitare a bureților poliuretanici în
cavitatea abdominală.
Materiale și metode. Lucrarea se bazează pe observarea a doi pacienți la care fragmente de burete poliuretanic au fost reținute în
cavitatea abdominală după tratamentul infecţiilor intraabdominale severe folosind un set TPPN improvizat necomercial.
Rezultate. Reţinerea accidentală a fragmentelor de burete poliuretanic în ambele cazuri a dus la formarea abceselor intraabdominale
peste 3 și 4 luni respectiv. Tehnicile imagistice medicale (scanare ultrasonoră și CT) nu au reușit să detecteze poliuretanul, iar
rezultatele au fost interpretate ca abcese abdominale tardive. Reintervenţiile pentru drenarea colecţiei purulente și extragerea
buretelui poliuretanic au fost însoțite de dificultăți tehnice crescute din cauza fibrozei severe, iar într-un caz a dus la apariția unei
fistule a intestinului subțire.
Concluzii. Pentru a umple uniform plăgile complexe cu material TPPN, bureții sunt adesea tăiați, făcând posibil ca bucățile de burete
rezidual să fie ușor trecute cu vederea și lăsate în urmă. Spre deosebire de obiectele textile, buretele poliuretanic nu are semnele
imagistice caracteristice și nu poate fi diagnosticat preoperator. Sistemele improvizate de TPPN trebuie evitate în favoarea celor
comerciale, iar toate fragmentele de burete rămase în plăgile abdominale trebuie înregistrate și notate minuţios. | en_US |
dc.description.abstract | Aim of study. Inadvertently leaving a textile matrix in the abdominal cavity represents one of the most serious and well-known surgical
errors. However, in recent years, the popularity of negative pressure wound therapy (NPWT) has grown significantly. The method
began to be actively used for severe intraabdominal infection, which led to cases of forgetting polyurethane sponges in the abdominal
cavity.
Materials and methods. The paper is based on the observation of two patients in whom polyurethane sponge fragments were
retained in the abdominal cavity after the treatment of severe intraabdominal infection using a non-commercial improvised NPWT set.
Results. Accidental retention of polyurethane sponge fragments in both cases resulted in intra-abdominal abscesses after 3 and
4 months respectively. Medical imaging studies (ultrasound and CT scanning) failed to detect polyurethane and the results were
interpreted as late abdominal abscesses. Repeated surgeries to drain the purulent collection and remove the polyurethane sponge
were accompanied by increased technical difficulties due to severe fibrosis, and in one case resulted in small bowel fistula appearance.
Conclusions. In order to evenly fill complex wounds with NPWT material, the sponges are often cut, making it possible for pieces of
residual sponge may be easily overlooked and be left behind. In contrast to the textile matrix, the polyurethane sponge does not have
characteristic imagine features and cannot be diagnosed preoperatively. Improvised NPWT systems should be avoided in favor of
commercial ones, and all sponge fragments left in abdominal wounds should be carefully recorded and noted. | en_US |
dc.publisher | Asociaţia chirurgilor “Nicolae Anestiadi” din Republica Moldova | en_US |
dc.relation.ispartof | Arta Medica: Al XIV-lea Congres al Asociației Chirurgilor „Nicolae Anestiadi” și al IV-lea Congres al Societății de endoscopie, chirurgie minim invazivă și ultrasonografie „V.M.Guțu” din Republica Moldova (cu participare internaţională), 21-23 septembrie 2023, Chișinău, Republica Moldova | en_US |
dc.subject | severe intraabdominal infection | en_US |
dc.subject | negative pressure wound therapy | en_US |
dc.subject | polyurethane sponge | en_US |
dc.subject | textiloma | en_US |
dc.subject | computed tomography | en_US |
dc.title | Textilom abdominal versus poliuretanom: diferențe semnificative | en_US |
dc.title.alternative | Abdominal textiloma versus polyurethanoma: significant differences | en_US |
dc.type | Other | en_US |
Appears in Collections: | Arta Medica Nr. 3(88) 2023
|