USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/2645
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDonici, Elena
dc.date.accessioned2019-06-24T20:56:41Z
dc.date.available2019-06-24T20:56:41Z
dc.date.issued2017
dc.identifier.citationDONICI, Elena. Elaborarea și validarea metodei spectrofotometrice în ultraviolet şi vizibil de dozare a fluocinolonului acetonid dintr-un unguent combinat: studiu experimental = Development and validation of spectrophotometric method in ultraviolet and visible of assay of fluocinolone acetonide from a combined ointment: experimental study. In: Revista de Ştiinţe ale Sănătăţii din Moldova. 2017, vol. 13(3), pp. 53-58. ISSN 2345-1467.en_US
dc.identifier.issn2345-1467
dc.identifier.urihttps://stiinta.usmf.md/sites/default/files/2018-09/MJHS%20nr.3_2017.pdf
dc.identifier.urihttp://repository.usmf.md/handle/20.500.12710/2645-
dc.descriptionCatedra de chimie farmaceutică și toxicologică, Universitatea de Stat de Medicină și Farmacie „Nicolae Testemiţanu”, Chișinău, Republica Moldovaen_US
dc.description.abstractRezumat Introducere. Cercetarea a fost inițiată cu scopul de a elabora și valida o metodă de dozare a fluocinolonului acetonid din unguentul combinat cu conținut de izohidrafural și fluocinolon acetonid. A fost selectată o metodă fizico-chimică modernă: spectroscopia în ultraviolet şi vizibil. Material şi metode. În cercetarea experimentală s-a utilizat unguentul combinat cu conținut de izohidrafural și fluo-cinolon acetonid, care a fost preparat în condiții de laborator. În calitate de substanțe active au servit fluocinolonul acetonid (Sigma Aldrich, concentrația 99,9%) și izohidrafuralul, sintetizat la Catedra de chimie organică a Universității de Stat din Moldova (concentrația 99,9%). De asemenea, s-a întrebuințat standardul analitic de fluocinolon acetonid (Sigma Aldrich, concentrația 99,9%). Aparatajul utilizat a constituit: spectrofotometrul Agilent Technologies 95-00, o pereche de cuve din cuarț cu grosimea stratului de 10 mm, balanță analitică OHAUS DV215 CD și veselă chimică de laborator. Rezultatele obținute au fost prelucrate statistic cu ajutorul programului SPSS 10.5. Rezultate. La înregistrarea spectrului în ultraviolet şi vizibil, fluocinolonul acetonid a prezentat în apă un maxim de absorbție la 241 nm. Metoda spectrofotometrică în ultraviolet şi vizibil elaborată a fost validată după parametrii: liniaritate, specificitate, limită de detecție, limită de cuantificare, precizie, acuratețe și robustețe. Concluzii. A fost elaborată o metodă spectrofotometrică în ultraviolet şi vizibil de dozare a fluocinolonului acetonid dintr-un unguent combinat cu izohidrafural. Rezultatele validării demonstrează că metoda elaborată este simplă, rapidă, exactă și reproductibilă. Astfel, metoda spectrofotometrică în ultraviolet şi vizibil, elaborată și validată, ar putea fi inclusă în Documentele Analitice de Normare a calității unguentului combinat cu conținut de izohidrafural și fluocinolon acetonid.en_US
dc.description.abstractAbstract Introduction. The research was initiated with the purpose of development and validation of a method of assay of fluocinolone acetonide from the combined ointment containing isohydrafural and fluocinolone acetonide. A modern physicochemical method has been selected: ultraviolet and visible spectroscopy. Material and methods. In experimental research, it wasused the combined ointment containing isohydrafural and fluocinolone acetonide, which was prepared under laboratory conditions. The active drug substances were fluocinolone acetonide (Sigma Aldrich, 99.9% concentration) and isohydrafural, which was synthesized at the Chair of organic chemistry of the State University of Moldova (99.9% concentration). It was used the apparatus: Agilent Technologies 95- 00 spectrophotometer, a pair of 10 mm quartz cuvettes, the OHAUS DV215 CD analytical torque and laboratory glassware. The obtained results were statistically processed using SPSS 10.5 software. Results. Fluocinolone acetonide had a maximum of absorbtion at 241 nm in water at the recording of the ultraviolet and visible spectrum. The developed ultraviolet and visible spectrophotometric method has been validated by the parameters: linearity, specificity, detection limit, quantification limit, precision, accuracy and robustness. Conclusions. It was developed a spectrophotometric method in ultraviolet and visible of assay of fluocinolone acetonide from a combined ointment containing isohydrafural. The results of validation demonstrate that the developed method is simple, rapid, accurate and reproducible. Thus, the developed and validated spectrophotometric method in ultraviolet and visible could be included in the Analytical Quality Control documents of the combined ointment containing isohydrafural and fluocinolone acetonide.
dc.language.isoroen_US
dc.publisherRevista de Științe ale Sănătății din Moldova = Moldovan Journal of Health Sciencesen_US
dc.subjectfluocinolone acetonideen_US
dc.subjectassayen_US
dc.subjectointmenten_US
dc.subjectultraviolet and visible spectrophotometryen_US
dc.subjectvalidationen_US
dc.subjectisohydrafuralen_US
dc.titleElaborarea și validarea metodei spectrofotometrice în ultraviolet şi vizibil de dozare a fluocinolonului acetonid dintr-un unguent combinat: studiu experimentalen_US
dc.title.alternativeDevelopment and validation of spectrophotometric method in ultraviolet and visible of assay of fluocinolone acetonide from a combined ointment: experimental studyen_US
dc.typeArticleen_US
Appears in Collections:Revista de Științe ale Sănătății din Moldova : Moldovan Journal of Health Sciences 2017 nr. 13(3)

Files in This Item:
File Description SizeFormat 
Elaborarea_si_validarea_metodei_spectrofotometrice_in_ultraviolet_si_vizibil.pdf426.85 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback