USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/28570
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSîrbu Vasile-
dc.date.accessioned2024-10-28T12:50:28Z-
dc.date.accessioned2024-11-18T15:08:40Z-
dc.date.available2024-10-28T12:50:28Z-
dc.date.available2024-11-18T15:08:40Z-
dc.date.issued2024-
dc.identifier.citationSîrbu Vasile. Diagnostic accuracy of xpert ultra for microbiological confirmation of pulmonary tuberculosis in patients with paucibacillary disease. In: Abstract Book. MedEspera 2024. The 10th International Medical Congress for Students and Young Doctors. 24-27 April 2024, Chișinău, Republic of Moldova, p. 150. ISBN 978-9975-3544-2-4.en_US
dc.identifier.isbn978-9975-3544-2-4-
dc.identifier.urihttps://ibn.idsi.md/collection_view/3104-
dc.identifier.urihttp://repository.usmf.md/handle/20.500.12710/28570-
dc.descriptionUniversitatea de Stat de Medicină şi Farmacie „Nicolae Testemiţanu”, Chişinău, Republica Moldovaen_US
dc.description.abstractIntroduction. Worldwide, up to one-third of pulmonary tuberculosis patients are missed for microbiological confirmation. Assessment of specimens obtained during bronchoscopy is one of the well-recognized methods that can increase the rate of microbiological confirmation in pulmonary tuberculosis. The data on the diagnostic accuracy of Xpert MTB Ultra, a real-time PCR-based diagnostic tool, in bronchial aspirate specimens is very limited. Aim of study. In the presented study, we have evaluated the performance of Xpert MTB Ultra in bronchial aspirate samples in patients with negative smear microscopy and Xpert MTB Ultra in freely expectorated sputum. Methods and materials. We retrospectively reviewed microbiological and basic clinical characteristics of all patients who were consulted for suspected pulmonary tuberculosis at the Institute of Phthtisiopneumology in Moldova during 2022 and had both negative smear and Xpert Ultra results in sputum samples and in whom bronchial aspirate was obtained by bronchoscopy with further microbiological examination by Xpert MTB Ultra and culture for M. tuberculosis. Results. 393 cases with a complete dataset have been analyzed, of which 80 have been diagnosed with pulmonary tuberculosis. Positive culture for M. tuberculosis was obtained in 2.5%, smear microscopy was positive in 1.8% (13 cases), and Xpert Ultra in 4.2% (30 cases) of bronchial aspirate samples. The sensitivity and specificity of Xpert Ultra in bronchial aspirate, using culture as a reference standard, were correspondingly 80.0% (95% CI, 37.5% – 99.0%) and 98.7% (95% CI, 97.0% - 99.4%). Additional microbiological confirmation of pulmonary tuberculosis was obtained in 11.2% (9/80) of the patients diagnosed with pulmonary TB. Conclusion. Xpert MTB Ultra has good diagnostic accuracy in bronchial aspirate samples. That could improve the rate of microbiological confirmation and potentially reduce the time to treatment initiation in patients with pulmonary tuberculosis. microbiological confirmation. Assessment of specimens ob tained during bronchoscopy is one of the well-recognized methods that can increase the rate o f microbiological confirmation in pulmonary tuberculosis. The data on the diagnostic accura cy of Xpert MTB Ultra, a real-time PCR-based diagnostic tool, in bronchial aspirate specime ns is very limited. Aim of study. In the presented study, we have evaluated the performance o f Xpert MTB Ultra in bronchial aspirate samples in patients with negative sm ear microscopy and Xpert MTB Ultra in freely expectorated sputum. Methods and materials. We retrospectively reviewed microbiological and basic clin ical characteristics of all patients who were consulted for suspected pulmonary tuberculosis at the Institute of Phthtisiopneumology in Moldova during 2022 and h ad both negative smear and Xpert Ultra results in sputum samples and in whom bronchial as pirate was obtained by bronchoscopy with further microbiological examination by Xpert MTB Ultra and culture for M. tuberculosis. Results. 393 cases with a complete dataset have been analyzed, of whi ch 80 have been diagnosed with pulmonary tuberculosis. Positive culture for M. t uberculosis was obtained in 2.5%, smear microscopy was positive in 1.8% (13 cases), and Xpert Ultra in 4.2% (30 cases) of bronchial aspirate samples. The sensitivity and specificity of Xper t Ultra in bronchial aspirate, using culture as a reference standard, were correspondingly 80.0% (95% CI, 37. 5% – 99.0%) and 98.7% (95% CI, 97.0% - 99.4%). Additional microbiological confirmation of pulmonary tuberculosis was obtained in 11.2% (9/80) of the patients diagnosed with pulmon ary TB. Conclusion. Xpert MTB Ultra has good diagnostic accuracy in bronchial as pirate samples. That could improve the rate of microbiological confirmation a nd potentially reduce the time to treatment initiation in patients with pulmonary tuberculosis.en_US
dc.publisherInstituţia Publică Universitatea de Stat de Medicină şi Farmacie „Nicolae Testemiţanu” din Republica Moldovaen_US
dc.relation.ispartofMedEspera 2024en_US
dc.titleDiagnostic accuracy of xpert ultra for microbiological confirmation of pulmonary tuberculosis in patients with paucibacillary diseaseen_US
dc.typeOtheren_US
Appears in Collections:MedEspera 2024

Files in This Item:
File Description SizeFormat 
MEsp24_150.pdf343.55 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback