USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/31279
Full metadata record
DC FieldValueLanguage
dc.contributor.authorZorina, Zinovia-
dc.contributor.authorBabuci, Angela-
dc.contributor.authorCatereniuc, Ilia-
dc.contributor.authorBendelic, Anastasia-
dc.contributor.authorStratulat, Silvia-
dc.contributor.authorOstahi, Nadia-
dc.contributor.authorBotnari, Tatiana-
dc.contributor.authorBotnaru, Doina-
dc.date.accessioned2025-10-23T15:51:27Z-
dc.date.available2025-10-23T15:51:27Z-
dc.date.issued2025-
dc.identifier.citationZORINA, Zinovia, Angela BABUCI; Ilia CATERENIUC; Anastasia BENDELIC; Silvia STRATULAT; Nadia OSTAHI; Tatiana BOTNARI și Doina BOTNARU. Particularități individuale ale indicilor morfometrici ai arterei axilare. In: Probleme actuale ale morfologiei. Materialele Conferinței științifice internaționale dedicată aniversării a 80 de ani de la fondarea Universității de Stat de Medicină și Farmacie „Nicolae Testemițanu” din Republica Moldova. Chișinău, 17-18 octombrie, 2025 (sub red. Ilia Catereniuc). Chișinău, 2025, pp. 286-290.en_US
dc.identifier.urihttps://repository.usmf.md/handle/20.500.12710/31279-
dc.description.abstractBackground Lately, the radial artery has been increasingly used in coronary angiography and in cases when its diameter is too small, or there occurs a spasm after the introduction of the contrast medium, the axillary artery is used. In order to avoid injury to the brachial plexus during catheterization of the axillary artery, it is necessary to know both the anatomo-topographic peculiarities and its morphometric parameters. The aim of the study was to evaluate the morphometric parameters of the axillary artery and of its branches depending on gender and constitutional type. Material and methods The upper limb arteries were studied on 210 angiographies of both genders, taken from the database of the Euromed Diagnostic Medical Center, Chisinau, Republic of Moldova. By determining the proportionality index of the humerus thickness/length, three constitutional types were established. Using the RadiAnt DICOM Viewer 3.42 software, the length of the axillary artery, its proximal/distal internal diameter, as well as the proximal internal diameter of all its branches were determined. Results The mean length of the axillary artery was 8.69±0.15 cm; in males – 8.98±0.18 cm, in females – 8.25±0.25 cm. The proximal internal diameter of the axillary artery was 7.82±0.16 mm, and the distal one – 6.38±0.14 mm; depending on gender, its proximal diameter was 8.08±0.20 mm in males and 7.40±0.24 mm in females, and the distal one – 6.6±0.19 mm in males and 6.03±0.20 mm in females. Conclusions Advanced imaging methods have the capacity for precise description of the individual peculiarities of the axillary artery morphometric parameters.en_US
dc.language.isoroen_US
dc.publisherInstituţia Publică Universitatea de Stat de Medicină şi Farmacie „Nicolae Testemiţanu” din Republica Moldovaen_US
dc.relation.ispartofProbleme actuale ale morfologiei. Conferință științifică internațională dedicată aniversării a 80 de ani de la fondarea Universității de Stat de Medicină și Farmacie „Nicolae Testemițanu” din Republica Moldova. Chișinău, 17-18 octombrie, 2025en_US
dc.subjectaxillary arteryen_US
dc.subjectmorphometric parametersen_US
dc.subjectconstitutional typeen_US
dc.titleParticularități individuale ale indicilor morfometrici ai arterei axilareen_US
dc.typeArticleen_US
Appears in Collections:Probleme actuale ale morfologiei. Materialele Conferinței științifice internaționale dedicată aniversării a 80 de ani de la fondarea Universității de Stat de Medicină și Farmacie „Nicolae Testemițanu” din Republica Moldova. Chișinău, 17-18 octombrie, 2025



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback