Title: The development of low-cost simulators for medical training in punctures
Authors: Adam, Alexandru
Gonta, Kristi
Florea, Constantin
Prozorovschi, Daniel
Nacu, Viorel
Keywords: anatomy;low-cost;simulation;punctures;practice
Issue Date: 2026
Publisher: CEP Medicina
Citation: ADAM, Alexandru, Kristi GONTA, Constantin FLOREA, Daniel PROZOROVSCHI and Viorel NACU. The development of low-cost simulators for medical training in punctures. In: Cells and Tissues Transplantation. Actualities and Perspectives: The Materials of the National Scientific Conference with International Participation, the 4 th edition, Chisinau, March 20-21, 2026. Chișinău : CEP Medicina, 2026, p. 11. ISBN 978-9975-82-477-4 (PDF).
Abstract: Introduction. Medical procedures involving punctures require practical training for outmost effectiveness and low risks. Therefore, a project with the purpose of training medical students was developed constructing 4 low-cost simulators for the following procedures: thoracocentesis, pericardiocentesis, femoral artery cannulation, and urinary bladder puncture. Materials and methods. The project was undergone using low-cost materials: mannequin structures, artificial skeletons, polysiloxane polymers, tubes, and reservoirs. The pericardial and pleural puncture simulators were made using an artificial skeleton of the upper body that was covered in skinresembling silicone and filled with sponges and reservoirs for the pleural and pericardial cavity. Moreover, the femoral artery and bladder punctures were constructed using a mannequin of the inferior body that was carved up in the respective anatomical places, which were filled with tubes, polymers and reservoirs to resemble the femoral artery and the bladder. Results. Models respected the topography of the actual organs and anatomical structures of the human body. Punctures were performed by considering the anatomical landmarks for the correct needle placement and depth. Thoracocentesis was carried out by finding the intercostal spaces of the simulator, whilst for pericardiocentesis the stern and the costal arches were taken into account. For the femoral artery and bladder: the iliac crest, the umbilicus and the pubic bone were used to determine the needle direction and entry point. In order to assess the functionality of the simulators, procedures were practiced in different stages of the project: first by the developers and afterwards by students during scientific workshops. Performance was functional and closely resembling real-life medical scenarios. Students offered positive feedback, identifying correct anatomical landmarks, and aspiring the liquids into syringes accordingly. Conclusions. Low-cost medical simulators for several punctures were successfully incorporated in student medical training, taking into account key anatomical elements and clinical scenarios. Additional developments to the project could improve anatomical accuracy and efficiency.
metadata.dc.relation.ispartof: Cells and Tissues Transplantation. Actualities and Perspectives: The Materials of the National Scientific Conference with International Participation, the 4 th edition, Chisinau, March 20-21, 2026
URI: https://repository.usmf.md/handle/20.500.12710/33085
ISBN: 978-9975-82-477-4 (PDF)
Appears in Collections:Cells and Tissues Transplantation. Actualities and Perspectives: The Materials of the National Scientific Conference with International Participation, the 4 th edition, Chisinau, March 20-21, 2026

Files in This Item:
File Description SizeFormat 
THE_DEVELOPMENT_OF_LOW_COST_SIMULATORS_FOR_MEDICAL_TRAINING.pdf244.74 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback