USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/6767
Full metadata record
DC FieldValueLanguage
dc.contributor.authorChiaburu-Chiosa, Doina
dc.date.accessioned2019-09-11T13:51:28Z
dc.date.available2019-09-11T13:51:28Z
dc.date.issued2019
dc.identifier.citationCHIABURU-CHIOSA, Doina. Distortion products of otoacoustic emissions and their role in assessing hearing loss in young children. In: The Moldovan Medical Journal. 2019, vol. 62, no 2, pp. 7-10. ISSN 2537-6373. DOI: 10.5281/zenodo.3233904en_US
dc.identifier.issn2537-6373
dc.identifier.issn2537-6381
dc.identifier.urihttp://repository.usmf.md/handle/20.500.12710/6767
dc.identifier.urihttps://doi.org/10.5281/zenodo.3233904
dc.identifier.urihttp://moldmedjournal.md/wp-content/uploads/2019/06/Moldovan-Med-J-2019-Vol-62-No-2-Full-Issue.pdf
dc.descriptionDepartment of Otorhinolaryngology, Nicolae Testemitsanu State University of Medicine and Pharmacy, Chisinau, the Republic of Moldovaen_US
dc.description.abstractBackground: Hearing loss in children is far beyond the scope of otology, since audition is the basis of developing speech and cognitive abilities, as well as the child’s personality. Due to its incidence and severe consequences that often lead to disability, hearing loss remains an acute issue for scholars and specialists of various fields. Material and methods: There have been studied distortion products otoacoustic emissions in children from two groups: the control group included 30 children, aged between 1-36 months, with normal hearing; whereas the study group consisted of 110 children aged between 1-36 months with sensorineural deafness. Rezults: We studied auditory distortion products (ADP) in the control group of children, where prior impedance had excluded any middle ear pathology, whereas the medical history data regarding the functional development of the auditory system and behavioral audiometry showed normal hearing. We studied ADP at frequencies of 500; 750; 1000; 1500; 2000; 3000; 4000 and 6000 Hz. The analysis of the obtained results revealed some particularities of the ADPs according to the tested frequencies. Thus, ADPs recording that explores 1000 Hz; 1500Hz; 2000Hz; 3000Hz; 4000Hz and 6000Hz frequencies showed no difficulty, being 100% recorded in all children within the control group. The background noise varied from – 10 dB SPL to – 20 dB SPL. Low frequencies were difficult to assess due to a significant environmental noise which in some cases was higher than the ADP amplitude. Conclusions: As a result of ADP recording carried out in examined children, we conclude: the ADP recording, namely the “ADP audiogram” test, is an objective method with high sensitivity, which can be used in hearing screening in early childhood. The criterion for impaired hearing based on the “ADP audiogram” is the spectral interruption for frequencies higher than 1000 Hz.en_US
dc.language.isoenen_US
dc.publisherThe Scientific Medical Association of the Republic of Moldovaen_US
dc.relation.ispartofThe Moldovan Medical Journal
dc.subjectdistortion productsen_US
dc.subjectotoacoustic emissionsen_US
dc.subjecthearing lossen_US
dc.subjectchildrenen_US
dc.subject.ddcUDC: 616.28-008.1-053.2
dc.subject.meshHearing Lossen_US
dc.subject.meshСhilden_US
dc.subject.meshOtoacoustic Emissions, Spontaneousen_US
dc.subject.meshDeafnessen_US
dc.subject.meshAuditory Perceptionen_US
dc.subject.meshHearing Testsen_US
dc.titleDistortion products of otoacoustic emissions and their role in assessing hearing loss in young childrenen_US
dc.typeArticleen_US
Appears in Collections:The Moldovan Medical Journal, Vol. 62, No 2, June 2019

Files in This Item:
File Description SizeFormat 
Distortion_products_of_otoacoustic_emissions_and_their_role.pdf1.4 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback