USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/9826
Full metadata record
DC FieldValueLanguage
dc.contributor.authorOprea, Vasile
dc.contributor.authorValica, Vladimir
dc.contributor.authorCheptanaru, Constantin
dc.contributor.authorNistorica, Mihai
dc.contributor.authorOprea, Sergiu
dc.contributor.authorMovila, Liviu
dc.date.accessioned2020-05-26T05:57:42Z
dc.date.available2020-05-26T05:57:42Z
dc.date.issued2020
dc.identifier.citationOPREA, Vasile, VALICA, Vladimir, CHEPTANARU, Constantin, et al. Automatic amperometric titration method for quantitative determination of zinc oxide in ointments. In: The Moldovan Medical Journal. 2020, vol. 63, no 1, pp. 13-18. ISSN 2537-6373. DOI: 10.5281/zenodo.3685650en_US
dc.identifier.issn2537-6373
dc.identifier.issn2537-6381
dc.identifier.urihttp://moldmedjournal.md/wp-content/uploads/2020/06/Mold-Med-J-March-2020-Vol-63-No-1-Full-Issue-version-5-of-10-06-20.pdf
dc.identifier.urihttp://repository.usmf.md/handle/20.500.12710/9826
dc.identifier.urihttps://doi.org/10.5281/zenodo.3685650
dc.descriptionDepartment of General Chemistry, Department of Pharmaceutical Chemistry and Toxicology, Scientific Center for Drug Research, Nicolae Testemitsanu State University of Medicine and Pharmacy, Medicines and Medical Devices Agency, Chisinau, the Republic of Moldova, Department of Informatics and Information Management, Academy of Economic Studies of Moldova Chisinau, the Republic of Moldovaen_US
dc.description.abstractBackground: Zinc is an important trace mineral in human body, therefore development of new methods for zinc determination in drugs is an actual task. Material and methods: Assay of standard solutions of zinc ions and solutions of ointments to be analyzed was performed automatically using the titrator TITRION, which recorded, then displayed on the screen each amperometric titration curve. The titration curves had a sudden break in the current intensity at the equivalence point, caused by anodic oxidation of the titrant and cathodic reduction of H+ at pH 3 – 4. The stoichiometry of Zn2+ ion sedimentation reaction with [Fe(CN)6 ]4- ions was studied and confirmed in the presence of the background electrolyte and the ZnO calculation formulas in the analyzed ointments were deduced. Results: Two different ointment masses were weighed for the Zoxitin ointment and the separate calculation results were 0.4172±0.0051 g/g and 0.4212±0.0051 g/g of ointment, and in the zinc oxide ointment ω(ZnO) was 10.208±0.078 %.These results were compared with the results of ZnO analysis in ointment by the classical complexometric titration method. For the Zoxitin ointment m(ZnO) was 0.4223±0.007 g/g of ointment, and for the ointment with ZnO ω(ZnO) was 10.18±0.11%. Conclusions: An automatic amperometric titration method was developed to quantify ZnO in ointments. The method is based on the sedimentation reaction of zinc ions with potassium ferrocyanide solution in presence of acetate buffer solution as background electrolyte.en_US
dc.language.isoenen_US
dc.publisherThe Scientific Medical Association of the Republic of Moldovaen_US
dc.relation.ispartofThe Moldovan Medical Journal
dc.subjectautomatic amperometric titrationen_US
dc.subjectzinc oxideen_US
dc.subjectquantitative determination of Znen_US
dc.subject.ddcUDC: 615.454.1.074:546.47-31+543.553.4en_US
dc.subject.meshZinc Oxideen_US
dc.subject.meshOxidesen_US
dc.subject.meshOintments--chemistryen_US
dc.subject.meshPharmaceutical Preparationsen_US
dc.subject.meshPharmacologyen_US
dc.subject.meshQuality Controlen_US
dc.titleAutomatic amperometric titration method for quantitative determination of zinc oxide in ointmentsen_US
dc.typeArticleen_US
Appears in Collections:The Moldovan Medical Journal, Vol. 63, No 1, March 2020



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback