dc.contributor.author |
Dvali, Merab |
|
dc.contributor.author |
Mekvabishvili, Giorgi |
|
dc.date.accessioned |
2023-04-03T07:39:12Z |
|
dc.date.available |
2023-04-03T07:39:12Z |
|
dc.date.issued |
2021 |
|
dc.identifier.citation |
DVALI, Merab, MEKVABISHVILI, Giorgi. TECNIS Eyhance - premium IOL at a reasonable price. In: 19th Black Sea Ophthalmological Society Congress, September 24-26, 2021, Chisinau, Republic of Moldova: abstract book, p. 20. |
en_US |
dc.identifier.uri |
http://repository.usmf.md/handle/20.500.12710/24037 |
|
dc.identifier.uri |
https://aom.md/wp-content/uploads/2021/10/ABSTRACT-BOOK_web.pdf |
|
dc.description.abstract |
Purpose: To evaluate the visual quality and performance after bilateral implantation of TECNIS
Eyhance IOL Model ICB00 (Johnson & Johnson Vision, Santa Ana, Ca ,USA) with or without
micro-monovision.
Design: Prospective, non-randomized clinical study.
Methods: The study comprised 31 patients. The subjects were divided into 2 sub-groups: Group
1 (n=16) who received bilateral implantation of TECNIS Eyhance IOL, targeted for emmetropia
in both eyes, Group 2 (n=15) received bilateral implantation of TECNIS Eyhance IOL, with the
target refraction of -0.75D in non-dominant eye (Blended Vision). The aim of the study was to
evaluate and compare binocular Uncorrected Distance Visual Acuity (UCDVA), Uncorrected
Intermediate Visual Acuity (UIVA) at 66 cm distance, Uncorrected Near Visual acuity (UCNVA)
at 40 cm distance, the presence of photic phenomena (Halos, Glares, Starbursts, negative
dysphotopsia) in both groups at 6 months postoperatively.
Results: There was no statistically significant difference observed between the 2 sub-groups in
terms of binocular UCDVA: -0.03 vs 0.00 LogMAR. UCIVA was comparable between the
groups: 0.15 LogMAR vs 0.14 LogMAR, (p < 0.001) respectively. In Group 2, patients had
significantly better UCNVA (0.21 LogMAR vs 0.58 LogMAR) (p < 0.01). In regards to
dysphotopsia profile, 1 patient in Group 1 complained of crescent-shaped shadowing in temporal
hemifield (negative dysphotopsia), which did not resolve after 6 months postoperatively, and 1
patient from Group 1 complained of glare sensitivity.
Conclusion: TECNIS Eyhance IOL provided an excellent and equal binocular UCDVA in Group
1 and Group 2. Though TECNIS Eyhance IOL yielded good binocular UCIVA, no statistically
significant difference was found between Group 1 and Group 2 in that regard. Group 1
demonstrated significantly better UCNVA compared to Group 2. Overall incidence and severity
of photic phenomena was low. |
en_US |
dc.language.iso |
en |
en_US |
dc.publisher |
Black Sea Ophthalmological Society, Ophthalmological Association from Moldova, Nicolae Testemitanu State University of Medicine and Pharmacy of the Republic of Moldova |
en_US |
dc.relation.ispartof |
19th Black Sea Ophthalmological Society Congress, September 24-26, 2021 Chisinau, Republic of Moldova |
en_US |
dc.title |
TECNIS Eyhance - premium IOL at a reasonable price |
en_US |
dc.type |
Other |
en_US |