USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/10687
Title: Ultrasound assessment of normal adnexa torsion
Authors: Puiu, Serghei
Keywords: Adnexal torsion;Ultrasound;Spontaneous detorsion
Issue Date: 2018
Publisher: The Scientific Medical Association of the Republic of Moldova
Citation: PUIU, Serghei. Ultrasound assessment of normal adnexa torsion. In: The Moldovan Medical Journal. 2018, vol. 61, RMI Congress Issue, p. 62. ISSN 2537-6381.
Abstract: Background: Adnexal torsion is a common gynecologic emergency. The evolution of torsion is unpredictable from complete spontaneous detorsion (rarely) to rapid progression and necrosis. Persistence at the stage of edema for several days is also possible. Prompt diagnosis and surgery are important, particularly in young fertile patients to preserve ovarian viability. The purpose of this study was to evaluate the ultrasound features of normal adnexa torsion. Material and methods: The study included 7 women of reproductive age (including 2 pregnant), referred for ultrasound assessment of clinically suspected adnexal torsion. Out of 7 patients, 6 underwent subsequent laparoscopy. Absence of any additional ovarian pathology was confirmed by both ultrasound and intraoperative inspection. The ultrasound description included ovarian volume, vascularization, ovarian stroma and parenchyma aspect, ‘‘whirlpool sign’’ and tubal edema. Results: Out of 7 cases, 6 were operated on and the diagnosis was confirmed, including 2 detorsions. In one case spontaneous detorsion has occurred with complete regression of edema within 1 month. Two sonographic patterns of twisted ovaries were noted: (1) unilaterally enlarged ovary with peripherally displaced follicles – noted in 4 cases, including in 2 patients with over 48 hrs after onset of symptoms, and (2) solid-appearing heterogeneous mass with echogenic and/or hypoechoic areas – noted in 3 cases. The “whirlpool sign” was present in 3 patients and tubal edema was present in 1 patient with normal adnexa torsion. Blood flow in the affected ovary was completely absent in only 3 patients. Conclusions: Ultrasound appearance of normal adnexa torsion may vary according to the duration of the condition. Recognition of different sonographic features of twisted normal adnexa may improve the diagnosis.
metadata.dc.relation.ispartof: The Moldovan Medical Journal: The IVth Congress of Radiology and Medical Imaging of the Republic of Moldova with international participation, Chisinau, May 31 – June 2, 2018
URI: http://moldmedjournal.md/wp-content/uploads/2018/05/The-Moldovan-Medical-Journal-vol-61-mai.pdf
http://repository.usmf.md/handle/20.500.12710/10687
ISSN: 2537-6381
2537-6373
Appears in Collections:The Moldovan Medical Journal, Vol. 61, May 2018 RMI Congress Issue

Files in This Item:
File Description SizeFormat 
Ultrasound_assessment_of_normal_adnexa_torsion.pdf56.43 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback