USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/11365
Title: Diagnostic accuracy of computed tomography findings in premature infants with bronchopulmonary dysplasia
Authors: Crivceanscaia, Evghenia
Keywords: Bronchopulmonary dysplasia;Low radiation dose high-resolution chest CT;Mosaic lung parenchymal pattern
Issue Date: 2018
Publisher: The Scientific Medical Association of the Republic of Moldova
Citation: CRIVCEANSCAIA, Evghenia. Diagnostic accuracy of computed tomography findings in premature infants with bronchopulmonary dysplasia. In: The Moldovan Medical Journal. 2018, vol. 61, RMI Congress Issue, p. 69. ISSN 2537-6381.
Abstract: Background: Bronchopulmonary dysplasia (BPD) is the most common chronic lung disease in newborns and premature infants. Low radiation dose high-resolution chest computed tomography (CT) holds great potential for providing valuable information related to the severity of BPD in premature infants and guiding the treatment strategy. The study aimed to evaluate the chest CT findings in premature infants with bronchopulmonary dysplasia (BPD). Material and methods: The study included a total of 32 premature infants with BPD who underwent a high-resolution chest CT between January 2015 and February 2018. Their CT findings were analyzed and diagnostic value evaluated. Results: The 3 most frequent CT findings included: mosaic lung parenchymal pattern – noted in 93.8% (30/32) patients, bronchial wall thickening – noted in 90.6% (29/32) patients and subpleural triangular/linear opacities – noted in 87.5% (28/32) patients. The diagnostic accuracy of each CT finding was as follows: mosaic lung parenchymal pattern – 89.13% (95% CI from 76.43% to 96.38%), bronchial wall thickening – 85.42% (95% CI from 72.24% to 93.93%), subpleural triangular/linear opacities – 81.25% (95% CI from 69.54% to 89.92%). Conclusions: Low radiation dose high-resolution chest computed tomography provided valuable diagnostic information in premature infants with BPD. The most accurate diagnostic finding was the mosaic lung parenchymal pattern, which was frequently associated with bronchial wall thickening and subpleural triangular/linear opacities.
metadata.dc.relation.ispartof: The Moldovan Medical Journal: The IVth Congress of Radiology and Medical Imaging of the Republic of Moldova with international participation, Chisinau, May 31 – June 2, 2018
URI: http://moldmedjournal.md/wp-content/uploads/2018/05/The-Moldovan-Medical-Journal-vol-61-mai.pdf
http://repository.usmf.md/handle/20.500.12710/11365
ISSN: 2537-6381
2537-6373
Appears in Collections:The Moldovan Medical Journal, Vol. 61, May 2018 RMI Congress Issue

Files in This Item:
File Description SizeFormat 
Diagnostic_accuracy_of_computed_tomography_findings_in_premature_infants.pdf55.4 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback