USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/11730
Title: Compatibility determination of potassium orotate with spironolactone by high-performance liquid chromatography
Authors: Mazur, Ecaterina
Schmid, Martin
Uncu, Livia
Keywords: HPLC;combination;potassium orotate;spironolactone
Issue Date: 2020
Publisher: The Scientific Medical Association of the Republic of Moldova
Citation: MAZUR, Ecaterina, SCHMID, Martin, UNCU, Livia. Compatibility determination of potassium orotate with spironolactone by high-performance liquid chromatography. In: The Moldovan Medical Journal. 2020, vol. 63, no 4, pp. 35-42. ISSN 2537-6381. DOI: 10.5281/zenodo.4016810
Abstract: Background: Compatibility determination between active pharmaceutical ingredients (APIs) in fixed-dose combinations is an indispensable step in the elaboration. High-performance liquid chromatography provides information on possible interactions between APIs and their related interaction products. The purpose of the present study was to investigate the compatibility of potassium orotate in combination with spironolactone by a HPLC method. Material and methods: The detection was carried out using Liquid Chromatograph Agilent 1100 with UV-VIS detector and a RP-18 reversed column (250*4 mm, 5 μm), mobile phase of acetonitrile: phosphate buffer solution (pH=4.0) with the ratio 1:49 and 1:1, at flow rate 1 and 1.5 mL/min, injection volume 20 μL; potassium orotate and spironolactone substances were provided by Sigma Aldrich, USA. Results: Due to the developed method both separation and simultaneous qualitative and quantitative determination of APIs in the mechanical mixture were carried out. Spironolactone: retention time 6.9 min, concentration 98.1% (±0.21); potassium orotate: retention time 3.06 min, concentration 91.67% (±0.15). There were just well-separated symmetrical peaks of APIs and no additional peak in the chromatograms. Conclusions: There is compatibility between APIs. Further studies will be performed by other methods (DSC, FT-IF Spectrometry) to confirm the obtained result.
metadata.dc.relation.ispartof: The Moldovan Medical Journal: The 75th anniversary of Nicolae Testemitanu State University of Medicine and Pharmacy of the Republic of Moldova (1945-2020)
URI: https://doi.org/10.5281/zenodo.4016810
http://moldmedjournal.md/wp-content/uploads/2020/09/MMJ-Vol-63-No-4-Oct-2020.pdf
http://repository.usmf.md/handle/20.500.12710/11730
ISSN: 2537-6381
2537-6373
Appears in Collections:The Moldovan Medical Journal, Vol. 63, No 4, October 2020



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback