|
- IRMS - Nicolae Testemitanu SUMPh
- 1. COLECȚIA INSTITUȚIONALĂ
- MedEspera: International Medical Congress for Students and Young Doctors
- MedEspera 2022
Please use this identifier to cite or link to this item:
http://hdl.handle.net/20.500.12710/21178
Title: | Fit of screw - retained fixed partial denture in partial edentulism |
Authors: | Chaimov, Eden |
Issue Date: | 2022 |
Publisher: | Nicolae Testemitanu State University of Medicine and Pharmacy of the Republic of Moldova, Association of Medical Students and Residents e |
Citation: | CHAIMOV, Eden. Fit of screw - retained fixed partial denture in partial edentulism. In: MedEspera: the 9th International Medical Congress for Students and Young Doctors: abstract book. Chișinău: S. n., 2022, p. 352. |
Abstract: | Introduction. There are many ways to treat partially edentulous patients. In the last few decades, dental
implants have become a valuable option for prosthodontic rehabilitation. The use of endosseous dental
implants to replace natural teeth lost to periodontal disease, trauma, or complication of dental caries has
become a predictable form of prosthetic treatment. A lot of research studies have demonstrated that implant
prostheses represent a predictable and successful restorative solution for these cases. Passive fit of an
implant framework is one of the mechanical parameters expected to influence the longevity of an implant
prosthesis.
Aim of study. To review the published literature for investigating the accuracy of fit of screw-retained
fixed partial denture fabricated using different methods of manufacturing.
Methods and materials. A comprehensive electronic search was performed through PubMed
(MEDLINE). The following keywords were combined: “fixed prosthesis”, “implant,” “framework,” “fit,”
“accuracy,” “fitting surface,” “bridge,” and “screw - retained.
Results. A total of 30 articles were considered for review. After article selection, the relevant information
from each article was extracted. From the selected studies, several implant framework fabrication methods
were identified: conventional casting of metal alloys; sectioning and reconnection through soldering (the
sectioned framework is indexed and reconnected with fused solder), CAD/ CAM, which involves
fabricating the implant framework by means of computer numeric controlled milling; spark erosion, used
to refine the fitting surface of the framework and framework bonding to a prefabricated abutment cylinder,
where the framework body is constructed with space to accommodate a prefabricated cylinder and resin
bonding is used to attach the framework body to the cylinders
Conclusion. No method of manufacturing is ideal for fabrication of screw-retained fixed implant
frameworks in all aspects. Casting of metal alloys generally does not provide an acceptable implant
framework fit unless additional treatment is performed. The benefit of soldering is unclear and perhaps
replaced by laser welding. Spark erosion, CAD/CAM, and framework bonding to prefabricated cylinders
have great potential to overcome significant inaccuracies produced by the fabrication procedure and provide
implant frameworks with excellent fit. CAD/CAM provides better results. |
metadata.dc.relation.ispartof: | MedEspera: The 9th International Medical Congress for Students and Young Doctors, May 12-14, 2022, Chisinau, Republic of Moldova |
URI: | https://medespera.asr.md/en/books http://repository.usmf.md/handle/20.500.12710/21178 |
Appears in Collections: | MedEspera 2022
|
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
|