USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/23577
Title: Sisteme tehnologice inovaționale în prelevarea și procesarea corneei
Other Titles: Innovative technological systems in cornea collection and processing
Инновационные технологические системы в сборе и обработке роговицы
Authors: Cociug, Adrian
Macagonova, Olga
Dumbrăveanu, Lilia
Cușnir, Valeriu
Nacu, Viorel
Keywords: endothelial cells;culture medium;intraocular pressure;epithelial cells;stroma;bioreactor;eye bank
Issue Date: 2022
Publisher: Asociația Obștească "Economie, Management și Psihologie în Medicină" din Republica Moldova
Citation: COCIUG, Adrian, MACAGONOVA, Olga, DUMBRĂVEANU, Lilia, et al. Sisteme tehnologice inovaționale în prelevarea și procesarea corneei. In: Sănătate publică, economie şi management în medicină. 2022, nr. 1(92), pp. 32-37. ISSN 1729-8687. https://doi.org/10.52556/2587-3873.2022.1(92).05
Abstract: Rezumat. Dispozitivele și instrumentariul folosite în prelevarea și procesarea corneei sunt și vor fi una din necesitățile folosite de Banca de ochi. Analiza aparatajului și instrumentariului modern pentru prelevarea și procesarea corneei necesită un progres tehnologic și informațional ce tinde să modernizeze toate tipurile de dispozitive pentru a spori calitatea corneei, ceea ce permite o stocare ex vivo mai îndelungată, menținând în același timp viabilitatea straturilor corneei la nivel epitelial, stromal și endotelial. Bioreactoarele sunt dispozitive complexe care mențin depozitarea corneei ex vivo care sunt mai aproape de norma fiziologică. Multe studii arată că aceste dispozitive direct sau indirect influențează activitatea celulelor.
Summary. The devices and tools used in the cornea sampling and processing is and will be one of the requirements used by the Eye Bank. Analysis of modern corneal sampling and instrumentation requires technological and informational progress that tends to modernize all types of devices to induce increased corneal quality that provides longer ex vivo storage while maintaining the viability of corneal layers at the epithelial, stromal, and endothelial levels. Bioreactors are complex devices that maintain the storage of the cornea ex vivo that are closer to the physiological norm. Many studies show that the materials that are made of these devices directly or indirectly influence the activity of the cells.
Резюме. Устройства и инструменты, используемые для взятия проб и обработки роговицы, являются и будут одним из предметов первой необходимости, используемых Глазным банком. Анализ современных образцов роговицы и инструментов требует технологического и информационного прогресса, направленного на модернизацию всех типов устройств для повышения качества роговицы, что обеспечивает более длительное хранение ex vivo при сохранении жизнеспособности слоев роговицы на эпителиальном, стромальном и эндотелиальном уровнях. Биореакторы представляют собой сложные устройства, поддерживающие запасы роговицы ex vivo, близкие к физиологической норме. Многие исследования показывают, что эти устройства прямо или косвенно влияют на активность клеток.
metadata.dc.relation.ispartof: Sănătate Publică, Economie şi Management în Medicină
URI: http://revistaspemm.md/wp-content/uploads/2022/12/2022_192-RevistaSPEMM_Integrala.pdf
https://doi.org/10.52556/2587-3873.2022.1(92).05
http://repository.usmf.md/handle/20.500.12710/23577
ISSN: 1729-8687
Appears in Collections:Sănătate Publică, Economie şi Management în Medicină Nr. 1(92) / 2022

Files in This Item:
File Description SizeFormat 
SISTEME_TEHNOLOGICE_INOVATIONALE_IN_PRELEVAREA_SI_PROCESAREA_CORNEEI.pdf640.21 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback