USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/10369
Title: Schimbarea toleranţei la efort a cartilagiului platoului tibial în fracturile intraarticulare ale condililor tibiali
Other Titles: The tolerance modification in the effort of the cartilage of the tibial plateau in intra-articular fractures of tibial condyles
Authors: Erhan, Nicolae
Vetrilă, Viorel
Belous, Petru
Issue Date: 2009
Publisher: Asociaţia chirurgilor “Nicolae Anestiadi” din Republica Moldova
Citation: ERHAN, Nicolae, VETRILĂ, Viorel, BELOUS, Petru. Schimbarea toleranţei la efort a cartilagiului platoului tibial în fracturile intraarticulare ale condililor tibiali. Arta Medica. 2009, nr. 1(34) (supliment), pp. 56-58. ISSN 1810-1852.
Abstract: În lucrare este elucidat studiul proprietăţilor fizico-mecanice a catilagiului de platou tibial în fracturile de condili tibiali. Studiul a fost efectuat pe 10 transplanturi de cartulagiul normal colectat prin tehnica artroscopică din regiunile intacte ale platoului tibial şi 10 transplanturi de cartilagiul colectate din regiunea fracturii în fiecare tip de fractură conform clasificării AO. ASIF.(B1,B2,B3). În rezultatul studiului am determinat că în fracturile de tipul B1 toleranţa catilajiului la efort scade în mediu cu 28%, dar în tipul B2,B3 cu 35%.
In this work there is elucidated the study of the physical-mechanical cartilage of the tibial plateau in fractures of tibial condyles. The study was done based on 10 cartilage transplants, being normally collected with the help of the arthroscopic technique from the intact regions of the tibial plateau, and 10 cartilage transplants collected from the fracture’s region of each type of fracture according to the AO, ASIF, (B1, B2, B3) classification. As a result, I have determined that in the type B1 fractures the tolerance of the cartilage supposed to effort decreases in average with 28%, but in the B2, B3 types - with 35%.
URI: http://repository.usmf.md/handle/20.500.12710/10369
ISSN: 1810-1852
Appears in Collections:Arta Medica Vol. 34 No 1, 2009 supliment

Files in This Item:
File Description SizeFormat 
SCHIMBAREA_TOLERANTEI_LA_EFORT_A_CARTILAGIULUI.pdf149.9 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback