|
- IRMS - Nicolae Testemitanu SUMPh
- 1. COLECȚIA INSTITUȚIONALĂ
- MedEspera: International Medical Congress for Students and Young Doctors
- MedEspera 2020
Please use this identifier to cite or link to this item:
http://hdl.handle.net/20.500.12710/12244
Title: | Ultrasonographic intra-inter-variability on patients with Sarcopenia and autoimmune diseases |
Authors: | Budeanu, Razvan-Gabriel Jugariu, Anamaria-Romina |
Keywords: | Sarcopenia;ultrasonographic;Intraclass correlation coefficient |
Issue Date: | 2020 |
Publisher: | MedEspera |
Citation: | BUDEANU, Razvan-Gabriel, JUGARIU, Anamaria-Romina. Ultrasonographic intra-inter-variability on patients with Sarcopenia and autoimmune diseases. In: MedEspera: the 8th Internat. Medical Congress for Students and Young Doctors: abstract book. Chișinău: S. n., 2020, p. 157-158. |
Abstract: | Introduction. Sarcopenia is a muscle disease, which affect the muscle mass, strength and the
physical performance at the older patients. Ultrasound is a new research and accurate technique
for measure the muscle mass and quantity. The use of ultrasound was recently approved for
diagnosis of sarcopenia.
Aim of the study. The aim of this study is to evaluate intra and inter-variability for
ultrasonographic measured areas of biceps brachii (BB), rectus femoris (RF) and the diaphragm
(DF) end- expiratory and maximum-inspiratory.
Materials and methods. The study included 17 patients with autoimmune disease of
rheumatology department of County Hospital of Targu Mures, Romania. They were
ultrasonographic evaluated for a 5-day period (day 1 and day 5) on the biceps brachii, rectus
femoris and diaphragm DF (end- expiratory and maximum inspiratory) muscle to identify the
intra- inter-variability between the two operators. The study is a prospective, pure
observational, non-interventional and the statistical analysis was perform with Microsoft
Office Excel package, GraphPad Prism 6 and SPSS. Intraclass correlation coefficient (ICC)
was considered statistically significant if ICC>0,7.
Results. ICC proves good inter-observer variability (P&W2009) at the following levels: BB
right assessment 1 and 2 (0,755/0,847 p<0,0001), BB left assessment 1 and 2 (0,8/0,818
p<0,0001), RF right assessment 1 and 2 (0,858/0,927 p<0,0001), RF left assessment 1 and 2
(0,89/0,77 p<0,0001). Poor results were found on the diaphragm investigation: DF endexpiratory
evaluation 1 and 2 (0,42/0,65 p<0,0001), DF maximum inspiratory evaluation 1 and
2 (0,32/0,608 p<0,0001). Regarding the intra-reliability we obtain good statistically significant
results on the level of BB right 0,86, RF right 0,78 and RF left 0,78.
Conclusions. In conclusion biceps brachii and rectus femoris ultrasound showed a good interintra
variability and the results revealed a ultrasonographic skill improvement from day 1 to
day 5. |
URI: | https://medespera.asr.md/wp-content/uploads/ABSTRACT-BOOK.pdf http://repository.usmf.md/handle/20.500.12710/12244 |
Appears in Collections: | MedEspera 2020
|
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
|