USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/12244
Title: Ultrasonographic intra-inter-variability on patients with Sarcopenia and autoimmune diseases
Authors: Budeanu, Razvan-Gabriel
Jugariu, Anamaria-Romina
Keywords: Sarcopenia;ultrasonographic;Intraclass correlation coefficient
Issue Date: 2020
Publisher: MedEspera
Citation: BUDEANU, Razvan-Gabriel, JUGARIU, Anamaria-Romina. Ultrasonographic intra-inter-variability on patients with Sarcopenia and autoimmune diseases. In: MedEspera: the 8th Internat. Medical Congress for Students and Young Doctors: abstract book. Chișinău: S. n., 2020, p. 157-158.
Abstract: Introduction. Sarcopenia is a muscle disease, which affect the muscle mass, strength and the physical performance at the older patients. Ultrasound is a new research and accurate technique for measure the muscle mass and quantity. The use of ultrasound was recently approved for diagnosis of sarcopenia. Aim of the study. The aim of this study is to evaluate intra and inter-variability for ultrasonographic measured areas of biceps brachii (BB), rectus femoris (RF) and the diaphragm (DF) end- expiratory and maximum-inspiratory. Materials and methods. The study included 17 patients with autoimmune disease of rheumatology department of County Hospital of Targu Mures, Romania. They were ultrasonographic evaluated for a 5-day period (day 1 and day 5) on the biceps brachii, rectus femoris and diaphragm DF (end- expiratory and maximum inspiratory) muscle to identify the intra- inter-variability between the two operators. The study is a prospective, pure observational, non-interventional and the statistical analysis was perform with Microsoft Office Excel package, GraphPad Prism 6 and SPSS. Intraclass correlation coefficient (ICC) was considered statistically significant if ICC>0,7. Results. ICC proves good inter-observer variability (P&W2009) at the following levels: BB right assessment 1 and 2 (0,755/0,847 p<0,0001), BB left assessment 1 and 2 (0,8/0,818 p<0,0001), RF right assessment 1 and 2 (0,858/0,927 p<0,0001), RF left assessment 1 and 2 (0,89/0,77 p<0,0001). Poor results were found on the diaphragm investigation: DF endexpiratory evaluation 1 and 2 (0,42/0,65 p<0,0001), DF maximum inspiratory evaluation 1 and 2 (0,32/0,608 p<0,0001). Regarding the intra-reliability we obtain good statistically significant results on the level of BB right 0,86, RF right 0,78 and RF left 0,78. Conclusions. In conclusion biceps brachii and rectus femoris ultrasound showed a good interintra variability and the results revealed a ultrasonographic skill improvement from day 1 to day 5.
URI: https://medespera.asr.md/wp-content/uploads/ABSTRACT-BOOK.pdf
http://repository.usmf.md/handle/20.500.12710/12244
Appears in Collections:MedEspera 2020

Files in This Item:
File Description SizeFormat 
Budeanu_Razvan_Gabriel.pdf340.31 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback