DC Field | Value | Language |
dc.contributor.author | Stavila, C. | - |
dc.contributor.author | Minuti, A.E. | - |
dc.contributor.author | Herea, D.D. | - |
dc.contributor.author | Labusca, L. | - |
dc.contributor.author | Stoian, G. | - |
dc.contributor.author | Lupu, N. | - |
dc.contributor.author | Chiriac, H. | - |
dc.date.accessioned | 2023-05-10T10:35:07Z | - |
dc.date.available | 2023-05-10T10:35:07Z | - |
dc.date.issued | 2023 | - |
dc.identifier.citation | STAVILA,C., MINUTI, A. E., HEREA, D. D., et al. Reliable protocol for sample preparation to observe nanomaterial adherence to the surface of biological cells by using scanning electron microscopy. In: Cells and Tissues Transplantation. Actualities and Perspectives: the materials of the national scientific conf. with internat. participation, Chișinău: CEP Medicina. 2023, p. 39. ISBN 978-9975-82-313-5. | en_US |
dc.identifier.isbn | 978-9975-82-313-5 | - |
dc.identifier.uri | http://repository.usmf.md/handle/20.500.12710/24269 | - |
dc.description.abstract | Background. When assessing the interaction between nanomaterials and cells, an important step is to
image the effects induced by the material to the cell membrane. In order to evaluate the results of the
interaction process, scanning electron microscopy (SEM) is typically used. Commonly, an important step
during the preparation of biological cell samples for SEM is represented by the critical point drying,
which involves the replacement of the alcohol used for dehydration with an inert gas. This conventional
drying method is not only hard to accomplish, but it can lead to sample destruction if specific parameters
are not met. On the other hand, when assessing nanomaterials adhered to the cell membrane, the integrity
of the cell is not necessarily important, so a little cell deflation doesn’t affect the intended purpose of the
evaluation. Here, we describe a simple and more cost efficient method to prepare biological samples for
SEM imaging that preserves cell integrity and can be used to describe nanomaterials interaction with cell
surface.
Methods. Cells were grown on sterilized silica chips, after which the evaluated nanomaterial was added
to the cell culture media at least 24h for incubation. Afterwards, the samples were washed to eliminate
non-adhered nanomaterials, fixed with glutaraldehyde and osmium tetroxide, and dehydrated with
increasing concentrations of alcohol. The silica chips were then air dried in the biological safety hood
and in vacuum, followed by a sputter coat film of 5 nm of gold. The samples were imaged with a
scanning electron microscope.
Results. We were able to obtain well preserved biological cell samples, both with and without
nanomaterials adhered to the cell membrane surface. Nanomaterials such as magnetic nanoparticles and
magnetic nanowires were easily traceable on cell surface. Furthermore, the nanomaterials were clearly
observed in the images obtained, while the cell surface was not affected by the drying process applied.
Although the samples obtained using our method were characterized by a slight deflation of the cells, the
morphology of the cells is well preserved and the method is suitable for the evaluation of the interaction
between nanomaterials and cell surfaces.
Conclusions: We have described a novel cost efficient and easy to perform method for processing
biological samples for SEM imaging that preserves cell morphology and can be used for analyzing
nanoparticle and nanowires interaction with cell surface. | en_US |
dc.language.iso | en | en_US |
dc.publisher | CEP Medicina | en_US |
dc.relation.ispartof | „Cells and tissues transplantation. Actualities and perspectives” dedicated to the 10th anniversary of the founding of the Human Tissue and Cells Bank and to the 15th anniversary of the founding of the Laboratory of Tissue Engineering and Cells Culture of Nicolae Testemitanu State University of Medicine and Pharmacy of the Republic of Moldova, March 17-18th 2023, Chisinau, Republic of Moldova | en_US |
dc.subject | SEM imaging | en_US |
dc.subject | nanoparticles | en_US |
dc.subject | nanowires | en_US |
dc.subject | cell samples | en_US |
dc.title | Reliable protocol for sample preparation to observe nanomaterial adherence to the surface of biological cells by using scanning electron microscopy | en_US |
dc.type | Other | en_US |
Appears in Collections: | The Materials of the National Scientific Conference with International Participation „Cells and tissues transplantation. Actualities and perspectives”
|