|
- IRMS - Nicolae Testemitanu SUMPh
- 1. COLECȚIA INSTITUȚIONALĂ
- MedEspera: International Medical Congress for Students and Young Doctors
- MedEspera 2024
Please use this identifier to cite or link to this item:
http://hdl.handle.net/20.500.12710/28926
Title: | The use of biphasic cements in peri-implant contour grafting |
Authors: | Chihai Alexandrina Taba Talia |
Issue Date: | 2024 |
Publisher: | Instituţia Publică Universitatea de Stat de Medicină şi Farmacie „Nicolae Testemiţanu” din Republica Moldova |
Citation: | Chihai Alexandrina; Taba Talia. The use of biphasic cements in peri-implant contour grafting. In: Abstract Book. MedEspera 2024. The 10th International Medical Congress for Students and Young Doctors. 24-27 April 2024, Chișinău, Republic of Moldova, p. 525. ISBN 978-9975-3544-2-4. |
Abstract: | Introduction. Tooth loss over time leads to bone atrophy in the edentulous area, which involves bone degradation in thickness, width and height. This aspect served as a starting point for the discovery of different materials, which resemble the natural bone structure, biocompatible with the human body and suitable for restoring lost bone volume. However, integration of the grafting materials does not always correspond to the expected results. In order to isolate the periosteum from the graft different membranes are used, which increase both surgical difficulty and the cost of the surgery. Case statement. The case presentation is based on a female patient (39 years old) who complained about a missing tooth on the upper jaw (first premolar). After clinical and paraclinical (CBCT) examination, a bone defect was observed from the buccal aspect (class B by Misch) which required contour grafting. A biphasic cement was used as grafting material. After performing incision and flap reflection, the implant site was performed with osseo-densification drills in order to preserve as much bone as possible, a 4,0-12mm implant was placed with an insertion torque of 40Ncm. Biphasic cement was applied to the buccal side until the level of neighboring teeth buccal profile. After drying with a gauze, the flap was sutured and no membranes were used. An individual healing abutment was made. Control x-rays were performed postoperatively and 6 months later in order to evaluate the obtained results. Discussions. The obtained results showed good restoration of the alveolar ridge and stable result after 1 year follow-up. Due to its property to harden during drying, it was easy to handle and no membrane was necessary for isolation of the graft. Insignificant postoperative edema was present 2 days after the surgery. At 1 year follow-up, the level of alveolar ridge in the region of the implant preserved its contour, similar to the neighboring area. Conclusion. In small one-wall defects, the usage of biphasic cement showed good and predictable results. Beside the resorbable properties of this biomaterial, it can be a good option for contour grafting and can significantly decrease the operative time and costs due to hardening properties, which exclude the necessity of membrane usage. bone degradation in thickness, width and height. This aspec t served as a starting point for the discovery of different materials, which resemble the natural bone structure, biocompatible with the human body and suitable for restoring lost bone volu me. However, integration of the grafting materials does not always correspond to the expected results . In order to isolate the periosteum from the graft different membranes are used, which increa se both surgical difficulty and the cost of the surgery. Case statement. The case presentation is based on a female patient (39 years old) who complained about a missing tooth on the upper jaw (first premolar). After clinical and paraclinical (CBCT) examination, a bone defect was observed from the buccal as pect (class B by Misch) which required contour grafting. A biphasic cement was used as grafting mate rial. After performing incision and flap reflection, the implant site was performed with oss eo-densification drills in order to preserve as much bone as possible, a 4,0-12mm implant was placed wit h an insertion torque of 40Ncm. Biphasic cement was applied to the buccal side until the le vel of neighboring teeth buccal profile. After drying with a gauze, the flap was sutured and no membrane s were used. An individual healing abutment was made. Control x-rays were performed pos toperatively and 6 months later in order to evaluate the obtained results. Discussions. The obtained results showed good restoration of the alveola r ridge and stable result after 1 year follow-up. Due to its property to harden during dryi ng, it was easy to handle and no membrane was necessary for isolation of the graft. Ins ignificant postoperative edema was present 2 days after the surgery. At 1 year follow-up, the level o f alveolar ridge in the region of the implant preserved its contour, similar to the neighboring area. Conclusion. In small one-wall defects, the usage of biphasic cement sh owed good and predictable results. Beside the resorbable properties of this biomater ial, it can be a good option for contour grafting and can significantly decrease the operative time and costs due to hardening properties, which exclude the necessity of membrane usage. |
metadata.dc.relation.ispartof: | MedEspera 2024 |
URI: | https://ibn.idsi.md/collection_view/3104 http://repository.usmf.md/handle/20.500.12710/28926 |
ISBN: | 978-9975-3544-2-4 |
Appears in Collections: | MedEspera 2024
|
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
|