USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/29564
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPetru Cepoida-
dc.contributor.authorCristina Martîn-
dc.date.accessioned2024-12-19T12:50:28Z-
dc.date.accessioned2024-12-22T07:44:27Z-
dc.date.available2024-12-19T12:50:28Z-
dc.date.available2024-12-22T07:44:27Z-
dc.date.issued2024-
dc.identifier.citationPetru Cepoida; Cristina Martîn. INFLUENȚA DURATEI PERIOADEI PREANALITICE ASUPRA REZULTATELOR ANALIZELOR EFECTUATE CU APARATUL RAPIDPOINT 500 = THE INFLUENCE OF THE PRE-ANALYTICAL PERIOD DURATION ON THE RESULTS OF TESTS PERFORMED WITH THE RAPIDPOINT 500 DEVICE. In: Revista de Ştiinţe ale Sănătăţii din Moldova = Moldovan Journal of Health Sciences. 2024, vol. 11, Nr. 3, anexa 2, p. 553. ISSN 2345-1467.en_US
dc.identifier.issn2345-1467-
dc.identifier.urihttps://cercetare.usmf.md/sites/default/files/inline-files/MJHS_11_3_2024_anexa2__site.pdf-
dc.identifier.urihttp://repository.usmf.md/handle/20.500.12710/29564-
dc.descriptionUniversitatea de Stat de Medicină şi Farmacie „Nicolae Testemiţanu”, Chişinău, Republica Moldovaen_US
dc.description.abstractIntroducere. Considerând faptul că aparatul Rapidpoint 500 (Siemens, Germania) înregistrează analize în regim consecutiv, potențial apare problema deteriorării probelor în cazul duratei excesive a perioadei analitice. Scopul lu crării. Comparația rezultatelor testării unui număr de para metri biochimici, gazelor sangvine și echilibrului acido-bazic în funcție de durata perioadei preanalitice. Material și metode. Studiul s-a efectuat pe 14 pacienți (10 bărbați și 4 femei; vârsta: 39-65 de ani): analizele au fost cercetate peste 5-15 minute și peste 45-60 de minute din momentul colectării analizei de laborator. Au fost analizați 5 parametri biochimici: hematocrit, hemoglobină, natriu, kaliu, calciu ionizat, glucoză și gazele sangvine/echilibrul acido-bazic. Rezultate. Seturile de analize efectuate au relevat următoarele rezultate (M±ES) (5-15 minute vs 45-60 minute): hematocrit 33,65±1,67% vs 33,87±1,67% (p>0,05), hemoglobină 114,57±5,76 g/l vs 115,14±5,67 g/l (p>0,05), natriu 135,57±0,78 mmol/l vs 136,90±0,76 mmol/l (p>0,05), kaliu 4,49±0,27 mmol/l vs 4,31±0,33 mmol/l (p>0,05), glu coză 8,1±1,25 mmol/l vs 7,66±1,28 mmol/l (p>0,05). Studi ul gazelor sangvine și al echilibrului acido-bazic a relevat următoarele: pH 7,38±0,04 vs 7,36±0,05 (p>0,05), pCO 2 (mmHg) 40,66±2,85 vs 42,76±2,47 (p>0,05), pO 2 (mmHg) 70,85±3,36 vs 84,01±4,19 (p<0,01), HCO 3 std (mmol/l) 23,33±2,76 vs 22,70±3,11 (p>0,05), sO 2 (%) 79,94±6,52 vs 82,97±5,78 (p>0,05), FO 2 Hb (%) 78,55±4,23 vs 81,58±5,11 (p>0,05), FCOHb (%) 1,48±0,21 vs 1,39±0,24 (p>0,05), lactat (mmol/l) 1,42±0,12 vs 1,73±0,16 (p<0,05), lacuna anionică (mmol/l) 14,43±1,39 vs 17,14±1,32 (p<0,05). Con cluzie. Studiul statistic a demonstrat lipsa diferenței statistic veridice între valorile parametrilor studiați, indiferent de durata perioadei preanalitice. Diferența statistic semnificativă a fost înregistrată numai pentru unii indicatori ai gazelor sangvine, lactat și lacunei anionice.ro_RO
dc.description.abstractBackground. Since the Rapidpoint 500 (Siemens, Germany) performs analyses in a one-by-one regime, there is a po tential issue of sample deterioration in case of excessive du ration of preanalytical period. Objective of the study. Com parison of the test results of various biochemical parameters, blood gases and acid-base balance on the duration of the pre-analytical period. Material and methods. The study was conducted on 14 patients (10 men and 4 women; age: 39-65 years old): analyses were examined at 5-15 minutes and over 45-60 minutes from the time of sample collection. Five biochemical parameters were analyzed: hematocrit, hemoglobin, sodium, potassium, glucose, and blood gases/ acid-base balance. Results. The analysis sets revealed the following results (M±ES) (5-15 minutes vs 45-60 minutes): hematocrit 33.65±1.67% vs 33.87±1.67% (p>0.05), hemoglobin 114.57±5.76 g/l vs 115.14±5.67 g/l (p>0.05), sodium 135.57±0.78 mmol/l vs 136.90±0.76 mmol/l (p>0.05), potassium 4.49±0.27 mmol/l vs 4.31±0.33 mmol/l (p>0.05), glucose 8.1±1.25 mmol/l vs 7.66±1.28 mmol/l (p>0.05). Blood gas and acid-base balance studies yielded the following Results. pH 7.38±0.04 vs 7.36±0.05 (p>0.05), pCO2 (mmHg) 40.66±2.85 vs 42.76±2.47 (p>0.05), pO2 (mmHg) 70.85±3.36 vs 84.01±4.19 (p<0.01), HCO3- std (mmol/l) 23.33±2.76 vs 22.70±3.11 (p>0.05), sO2 (%) 79.94±6.52 vs 82, 97±5.78 (p>0.05), FO2Hb (%) 78.55±4.23 vs 81.58±5.11 (p>0.05), FCOHb (%) 1.48±0.21 vs 1.39±0.24 (p>0.05), lactate (mmol/l) 1.42±0, 12 vs 1.73±0.16 (p<0.05), anion gap (mmol/l) 14.43±1.39 vs 17.14±1.32 (p<0.05). Conclusion . The statistical study demonstrated the lack of significant statistical difference between the values of the studied parameters, regardless of the duration of the pre-analytical period. Statistically significant differences were observed only for certain blood gas parameters, lactate, and the anion gap.en_US
dc.publisherInstituţia Publică Universitatea de Stat de Medicină şi Farmacie „Nicolae Testemiţanu” din Republica Moldovaen_US
dc.relation.ispartofRevista de Științe ale Sănătății din Moldova = Moldovan Journal of Health Sciencesen_US
dc.subjectgeneral blood analysisen_US
dc.subjectdialysisen_US
dc.subjectacid-base balanceen_US
dc.titleINFLUENȚA DURATEI PERIOADEI PREANALITICE ASUPRA REZULTATELOR ANALIZELOR EFECTUATE CU APARATUL RAPIDPOINT 500ro_RO
dc.title.alternativeTHE INFLUENCE OF THE PRE-ANALYTICAL PERIOD DURATION ON THE RESULTS OF TESTS PERFORMED WITH THE RAPIDPOINT 500 DEVICEen_US
dc.typeOtheren_US
Appears in Collections:Revista de Științe ale Sănătății din Moldova : Moldovan Journal of Health Sciences 2024 Vol. 11, Issue 2

Files in This Item:
File Description SizeFormat 
MJHS_3_2024_A2_553.pdf188.57 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback