USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/29746
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAlina Cereniuc-
dc.contributor.authorDaniela Fornea-
dc.contributor.authorEcaterina Mazur-
dc.contributor.authorLivia Uncu-
dc.contributor.author-
dc.date.accessioned2024-12-19T12:50:28Z-
dc.date.accessioned2024-12-22T14:28:07Z-
dc.date.available2024-12-19T12:50:28Z-
dc.date.available2024-12-22T14:28:07Z-
dc.date.issued2024-
dc.identifier.citationAlina Cereniuc; Daniela Fornea; Ecaterina Mazur; Livia Uncu; . CERCETAREA PRECIZIEI ȘI A ROBUSTEȚEI LA VALIDAREA METODEI HPLC PENTRU DOZAREA PRINCIPIILOR ACTIVE DIN CAPSULE COMBINATE = RESEARCH OF PRECISION AND ROBUSTNESS IN THE VALIDATION OF THE HPLC DOSING METHOD OF ACTIVE INGREDIENTS IN COMBINED CAPSULES. In: Revista de Ştiinţe ale Sănătăţii din Moldova = Moldovan Journal of Health Sciences. 2024, vol. 11, Nr. 3, anexa 2, p. 745. ISSN 2345-1467.en_US
dc.identifier.issn2345-1467-
dc.identifier.urihttps://cercetare.usmf.md/sites/default/files/inline-files/MJHS_11_3_2024_anexa2__site.pdf-
dc.identifier.urihttp://repository.usmf.md/handle/20.500.12710/29746-
dc.descriptionUniversitatea de Stat de Medicină şi Farmacie „Nicolae Testemiţanu”, Chişinău, Republica Moldovaen_US
dc.description.abstractIntroducere. Pentru validarea metodei HPLC se determină robustețea, prin care se măsoară capacitatea unei metode de a rămâne neschimbată la modificări mici a unor parame tri. Precizia metodei se exprimă ca abatere standard relativă (RSD) a unei serii de măsurători. Scopul lucrării. Evaluar ea preciziei și robusteței în procesul de validare a metodei HPLC de dozare a capsulelor combinate cu nicergolină (NIC), piracetam (PIR) și extract de păducel (EP). Material și metode. NIC și PIR substanțe standard (Sigma-Aldrich, Germania), trei serii experimentale (01, 02, 03) de capsule operculate; reagenți și solvenți cu grad de puritate HPLC; sistem HPLC Shimadzu-20A cu detector UV-VIS (Japonia), coloană EC/Nucleosil C18 5μm (100* 4,6mm); faza mobilă: acetonitril : metanol : tampon fosfat pH 7,0 (40:35:25), tem peratura coloanei 30°C; volum de injectare 20 µl, debit fază mobilă – 1,5 ml/min; eluare izocratică; detecție la 288 nm pentru NIC și 220 nm pentru PIR. Rezultate. A fost evaluată repetabilitatea și precizia intermediară pentru 6 probe, RSD a fost calculat pentru timpul de retenție (1,91 min pentru PIR și 5,61 min pentru NIC), zona de vârf și concentrație, toate valorile fiind mai mici de 1%. Robustețea a fost determinată prin varierea condițiilor cromatografice: debitul fazei mobile cu±0,1 ml/min, cantitatea de acetonitril în faza mobilă cu±2% și temperatura coloanei cu±5°C. Rezultatele au arătat, că la o modificare minoră a condițiilor metodei metoda este robustă. S-a realizat o bună separare, iar valorile RSD sunt în limite și nu depășesc 2,0%. Concluzii. Rezultatele studiului au arătat, că metoda elaborată este precisă și robustă, fiind în corespundere cu cerințele ghidurilor ICH.ro_RO
dc.description.abstractBackground. To validate the HPLC method, robustness is determined, which measures the ability of a method to remain unchanged at small changes in some parameters. The precision of the method is expressed as the relative standard deviation (RSD) of a series of measurements. Objec tive of the study. Evaluation of precision and robustness in the process of validating the HPLC method of dosing combined capsules with nicergoline (NIC), piracetam (PIR) and hawthorn extract (HE). Assessment of precision and robust ness in the validation process of the HPLC method of dosing combined capsules with nicergoline (NIC), piracetam (PIR) and hawthorn extract (HE). Material and methods. NIC and PIR standard substances (Sigma-Aldrich, Germany), three experimental series (01, 02, 03) of capped capsules; HPLC grade reagents and solvents; Shimadzu-20A HPLC system with UV-VIS detector (Japan), EC/Nucleosil C18 col umn 5μm (100* 4.6mm); mobile phase: acetonitrile: methanol: phosphate buffer pH 7.0 (40:35:25), column tempera ture 30°C; injection volume 20 µl, mobile phase flow – 1.5 ml/min; isocratic elution; detection at 288 nm for NIC and 220 nm for PIR. Results. Repeatability and intermediate precision were assessed for 6 samples, RSD was calculated for retention time (1.91 min for PIR and 5.61 min for NIC), peak area and concentration, all values being less than 1 %. Robustness was determined by varying the chromatographic conditions: mobile phase flow rate by±0.1 ml/min, acetonitrile amount in the mobile phase by±2% and column temperature by±5°C. The results showed that the method is robust to a minor change in the conditions of the method. Good separation was achieved, and the RSD values were within limits and did not exceed 2.0%. Conclusions. The results of the study showed that the developed method is pre cise and robust, being in accordance with the requirements of the ICH guidelines.en_US
dc.publisherInstituţia Publică Universitatea de Stat de Medicină şi Farmacie „Nicolae Testemiţanu” din Republica Moldovaen_US
dc.relation.ispartofRevista de Științe ale Sănătății din Moldova = Moldovan Journal of Health Sciencesen_US
dc.subjectDosingen_US
dc.subjectHPLCen_US
dc.subjectvalidationen_US
dc.subjectprecisionen_US
dc.subjectrobustnessen_US
dc.titleCERCETAREA PRECIZIEI ȘI A ROBUSTEȚEI LA VALIDAREA METODEI HPLC PENTRU DOZAREA PRINCIPIILOR ACTIVE DIN CAPSULE COMBINATEro_RO
dc.title.alternativeRESEARCH OF PRECISION AND ROBUSTNESS IN THE VALIDATION OF THE HPLC DOSING METHOD OF ACTIVE INGREDIENTS IN COMBINED CAPSULESen_US
dc.typeOtheren_US
Appears in Collections:Revista de Științe ale Sănătății din Moldova : Moldovan Journal of Health Sciences 2024 Vol. 11, Issue 2

Files in This Item:
File Description SizeFormat 
MJHS_3_2024_A2_745.pdf215.15 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback