USMF logo

Institutional Repository in Medical Sciences
of Nicolae Testemitanu State University of Medicine and Pharmacy
of the Republic of Moldova
(IRMS – Nicolae Testemitanu SUMPh)

Biblioteca Stiintifica Medicala
DSpace

University homepage  |  Library homepage

 
Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12710/34646
Title: JUSTIFICATION AND OPTIMIZATION OF COMPUTED TOMOGRAPHY IN THE EVALUATION AND MONITORING OF ONCOLOGICAL PATIENTS
Authors: Moraru, Elizaveta
Keywords: computed tomography;oncological patient;dose optimization;oncological staging;radiation protection
Issue Date: 2026
Publisher: Centrul Editorial-Poligrafic Medicina
Citation: Moraru, Elizaveta. JUSTIFICATION AND OPTIMIZATION OF COMPUTED TOMOGRAPHY IN THE EVALUATION AND MONITORING OF ONCOLOGICAL PATIENTS. In: MedEspera 2026, p. 831. ISBN 978-9975-82-486-6.
Abstract: Introduction. Computed tomography (CT) is one of the main imaging modalities used in the evaluation and monitoring of oncological patients, playing a key role in detecting and confirming primary neoplastic processes, assessing loco-regional and distant spread, and evaluating treatment response. Justified and optimized CT use is essential to ensure adequate diagnostic quality while minimizing radiation exposure. Aim of study. To analyze the role of computed tomography in oncological patient evaluation and follow-up, focusing on justification and optimization principles. Methods and materials. This descriptive and analytical study included 96 oncological patients examined at the Municipal Hospital “Sfanta Treime”, Chisinau, Republic of Moldova. CT examinations were performed using 80-slice Toshiba and 128-slice GE scanners. The main indications for CT were detection and confirmation of primary neoplastic processes, evaluation of loco-regional and distant extension, and disease monitoring. The study included patients with histological confirmation as well as cases without histopathological diagnosis at imaging time. For primary diagnosis, contrast-enhanced thoraco-abdomino-pelvic CT with all scanning phases was preferred. During follow-up, previous imaging studies were reviewed to select only necessary phases, avoiding unnecessary acquisitions and reducing radiation dose. Optimization strategies also considered patient anamnesis and clinical data, with intravenous and oral contrast administered in 22 patients to improve diagnostic accuracy. Results. Computed tomography enabled accurate assessment of neoplastic processes, anatomical relationships, and disease spread. Protocol adaptation according to examination purpose maintained diagnostic quality while reducing radiation exposure. Adjustment of scanning parameters (kVp, automatic mA modulation, pitch, and collimation) optimized the image quality-dose ratio. Reduced dose parameters (CTDIvol and DLP) were observed particularly in follow-up examinations without compromising diagnostic image quality. The number of CT slices significantly influenced scanning time and radiation dose, with lower radiation exposure observed when using the 128 -slice CT system compared to the 80-slice scanner, consistent with findings reported in the literature. Image quality was considered diagnostically adequate in all analyzed cases. Conclusions. Computed tomography is an essential imaging modality in oncological patient management. Proper justification and optimization of CT protocols, including the use of advanced multislice CT systems and individualized scanning parameters, allow an optimal balance between diagnostic benefit and radiation risk. The radiology technician plays a key role in protocol implementation and radiation protection.
metadata.dc.relation.ispartof: MedEspera 2026. The 11th International Medical Congress for Students and Young Doctors, 6-8 May 2026
URI: https://medespera.md/documents/abstract-book-4.pdf
https://repository.usmf.md/handle/20.500.12710/34646
ISBN: 978-9975-82-486-6
Appears in Collections:MedEspera 2026

Files in This Item:
File Description SizeFormat 
M_831.pdf466.47 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback