Title: ALGORITHMIC STANDARDIZATION OF CARDIOTOCOGRAPHY USING THE AUTOMATED FISHER-KREBS SCORE AND ITS IMPACT ON INTRAPARTUM OBSTETRIC DECISIONS: A COMPARATIVE STUDY IN A LEVEL III PERINATAL CENTER (2025)
Authors: Teacă, Maria-Magdalina
Keywords: Cardiotocography;Fetal hypoxia;Obstetric interventions
Issue Date: 2026
Publisher: Centrul Editorial-Poligrafic Medicina
Citation: Teacă, Maria-Magdalina. ALGORITHMIC STANDARDIZATION OF CARDIOTOCOGRAPHY USING THE AUTOMATED FISHER-KREBS SCORE AND ITS IMPACT ON INTRAPARTUM OBSTETRIC DECISIONS: A COMPARATIVE STUDY IN A LEVEL III PERINATAL CENTER (2025). In: MedEspera 2026, p. 913. ISBN 978-9975-82-486-6.
Abstract: Introduction. Interpretation of cardiotocography (CTG) remains inherently subjective, influencing clinical decision-making in cases of suspected fetal compromise and contributing to variability in urgent cesarean section and operative vaginal delivery rates. The automated Fisher-Krebs scoring system, supported by artificial intelligence (AI), aims to standardize CTG evaluation by integrating clinical parameters with fetal heart rate patterns, thereby facilitating earlier identification of acute intrauterine hypoxia and supporting more consistent and evidence-based obstetric management. Aim of study. To compare the rate of obstetric interventions for fetal indications between CTG monitoring with automated Fisher-Krebs scoring and conventional clinician-interpreted CTG in a Level III perinatal center during 2025. Methods and materials. A retrospective cohort study included all 2025 deliveries in a Level III center. Two delivery wards were compared: Ward 1 - CTG with automated Fisher-Krebs scoring (n = 2,058); Ward 2 - conventional CTG (n = 2,164). Outcomes assessed were urgent cesarean sections and operative vaginal deliveries with vacuum extraction for suspected fetal hypoxia. Relative risk was expressed as odds ratios (OR) with 95% confidence intervals (CI); p < 0.05 was significant. Results. A total of 4,222 deliveries were analyzed: 2,058 in Ward 1, where automated Fisher-Krebs CTG analysis was implemented, and 2,164 in Ward 2 with conventional CTG interpretation. Urgent cesarean sections occurred in 21.0% of cases in Ward 1 compared with 24.4% in Ward 2. Cesarean sections for fetal hypoxia were significantly lower with automated CTG (2.7% vs. 4.8%; OR 0.54, 95% CI: 0.39-0.76; p < 0.001). Likewise, vacuum-assisted deliveries for fetal indications were less frequent in the automated CTG ward (1.1% vs. 3.0%; OR 0.37, 95% CI: 0.23-0.60; p < 0.001). Among urgent cesarean sections, fetal hypoxia accounted for 12.7% in the automated CTG ward compared with 19.7% in the conventional CTG ward. Conclusions. In this Level III center, automated Fisher-Krebs CTG was associated with nearly a 50% reduction in cesarean sections for fetal hypoxia and a significant decrease in operative vaginal deliveries for fetal indications. These findings underscore the clinical relevance of standardized, AI-assisted CTG interpretation in shaping intrapartum decision-making and improving the consistency of fetal heart rate assessment. Broader implementation of AI-based CTG analysis across delivery rooms may represent an effective strategy to optimize obstetric management and reduce potentially avoidable interventions. Further research is warranted to evaluate its impact on neonatal outcomes and overall perinatal safety.
metadata.dc.relation.ispartof: MedEspera 2026. The 11th International Medical Congress for Students and Young Doctors, 6-8 May 2026
URI: https://medespera.md/documents/abstract-book-4.pdf
https://repository.usmf.md/handle/20.500.12710/34727
ISBN: 978-9975-82-486-6
Appears in Collections:MedEspera 2026

Files in This Item:
File Description SizeFormat 
M_913.pdf467.23 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback