- IRMS - Nicolae Testemitanu SUMPh
- REVISTE MEDICALE NEINSTITUȚIONALE
- The Moldovan Medical Journal
- Curierul Medical 2009 - 2016
- Curierul Medical, 2014
- Curierul Medical, 2014, Vol. 57, Nr. 6
Please use this identifier to cite or link to this item:
http://hdl.handle.net/20.500.12710/7446
Title: | Capacităţile rezistenţional-deformative ale ductului biliar comun |
Other Titles: | Rezistentional deformation capacities of the human common bile duct |
Authors: | Suman, S. |
Keywords: | tensiometric researches;biomechanical peculiarities;common bile duct |
Issue Date: | 2014 |
Publisher: | The Scientific Medical Association of the Republic of Moldova |
Citation: | SUMAN, S. Capacităţile rezistenţional-deformative ale ductului biliar comun. In: Curierul Medical. 2014, vol. 57, no 6, pp. 19-24. ISSN 1875-0666. |
Abstract: | Background: The fundamental directions of biology and medicine long ago included in the sphere of their research the study of physico-mechanical
properties of the various anatomical structures. This information has direct use in medical practice, in the foreground in reparative interventions. At
the present stage it is difficult to name any anatomical structures which have no interest in reconstructive surgery. Furthermore, each organ or tissue,
viewed in terms of safety of biological materials, has certain tensometric parameter values that should be taken into consideration, including habitual daily
practice, alongside with the medical one. So the safety of the biological materials (less matters the system that it represents) is one of the determining
factors in adapting the organs to the new exceptional conditions of the ambient environment. At the present stage more and more anatomical structures
are the subject for the tensometric research.
Material and methods: Rezistentional-strain values of human common bile duct walls were established on a group comprising 30 cases. Ordinary
tensometric methods were practiced. The samples were subjected to mechanical stresses only in the longitudinal direction. The length of the samples
range from 4 to 6 cm. Kg/force unit of measurement was used. The limit resistance is determined by the ratio of the breaking strength in kg/f, and the
sample cross-sectional area expressed in mm2
. Relative extension was expressed in %.
Results: Analysis of data obtained showed the following values: d = 97.87:352.8 = 0.277 kgf/mm2 or 2.72 N/mm2
; e = 4.55:3.11 × 100 = 146.3%;
E = 277:146.3 = 1.893 gf/mm2 and 0.019 N/mm2
. So each sample was subjected to complete destruction under the action of the mechanical stresses which
vary between 2.2 kg and 4.7 kg – 19.62 and 46.11 N, or between 22 and 47 MPa.
Conclusions: There were set the major tensometric parameter values: force of destruction of evidence, the strength limit, maximum relative extension
and the rigidity coefficient (Young’s modulus). High resistance to mechanical stress opposes human common bile duct walls, no matter how the samples
were cut: strip-shaped or tubular segments (without dissecting them longitudinally). The force destruction of a sample strip is equivalent to 3.262 kg/f
and tubular samples – 4.076 kg/f. |
metadata.dc.relation.ispartof: | Curierul Medical |
URI: | http://repository.usmf.md/handle/20.500.12710/7446 http://moldmedjournal.md/wp-content/uploads/2016/09/Cm-6-2014-Electronic-version.pdf |
ISSN: | 1875-0666 |
Appears in Collections: | Curierul Medical, 2014, Vol. 57, Nr. 6
|
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
|