Title: Rezultatele la distanță și a toxicității în urma radiosensibilizării cancerului de col uterin local avansat, utilizând diferite tehnici de radioterapie externă conformațională (reviul literaturii)
Other Titles: Long term results and toxicity after radiosensibilization of locally advanced cervical cancer using different conformational external radiotherapy techniques (literature review)
Authors: Urechi, Virgiliu
Keywords: radiosensibilization;conformal external beam radiotherapy;cervical cancer;long term results;toxicity
Issue Date: 2019
Publisher: Asociaţia chirurgilor “Nicolae Anestiadi” din Republica Moldova
Citation: URECHI, Virgiliu. Rezultatele la distanță și a toxicității în urma radiosensibilizării cancerului de col uterin local avansat, utilizând diferite tehnici de radioterapie externă conformațională (reviul literaturii). In: Arta Medica. 2019, nr. 2(71), pp. 23-25. ISSN 1810-1852.
Abstract: Au fost studiate și prezentate rezultatele la distanță ale diferitor regimuri de radiochimioterapie, în concomitență cu agenți radiosensibilizanți, în regim de monopreparat sau al dupleților, în tratamentul cancerului de col uterin local avansat, utilizând diferite tehnici de radioterapie externă conformațională. A fost demonstrată superioritatea utilizării dupleților de radiosensibilizanți, în ceea ce privește supraviețuirea generală, și fără recidivă la pacientele cu cancer de col uterin local – avansat, totodată crescând incidența și severitatea toxicității postradice, ceea ce necesită continuarea studiilor în această direcție cu scop de ameliorare a rezultatelor tratamentului pe fon de toxicitate optimă. Tehnicile moderne de radioterapie externă optimizează volumul de iradiere scăzând incidența și severitatea toxicității.
The results of different chemoradiation regimens, concurrently with single-agent or duplets of radiosensitizers, in the treatment of locally advanced cervical cancer using various conformational external radiotherapy techniques have been studied and presented. The superiority of the use of duplets of radiosensitizers in overall and recurrence – free survival of patients with advanced local cervical cancer has been demonstrated, increasing the incidence and severity of postradic toxicity, which requires further studies in this direction with a view to ameliorating the results of treatment with optimal toxicity. Modern external beam radiotherapy techniques optimize the irradiated volume decreasing the incidence and severity of toxicity.
Изучены и представлены отдалённые результаты и токсичность различных режимов местной химиолучевой терапии – распространенного рака шейки матки с использованием различных радиомодификаторов, так в монорежиме, как и дуплексов, используя различные техники конформной лучевой терапии. Лучшие результаты выживаемости были достигнуты при применении дуплесков на протяжении дистанционной лучевой терапии, но с более высокой токсичностью со стороны здоровых тканей, что предполагает необходимость проведения углублённых исследований в этом направлении, для улучшения результатов на фоне переносимой токсичности. Современные технологии конформной дистанционной лучевой терапии позволяют оптимизировать объём облучения со снижением уровня лучевых повреждений, с сохранением хороших показателей выживаемости.
URI: https://artamedica.md/old_issues/ArtaMedica_71.pdf .
http://repository.usmf.md/handle/20.500.12710/9509
ISSN: 1810-1852
Appears in Collections:Arta Medica Vol. 71, No 2, 2019

Files in This Item:
File Description SizeFormat 
Urechi_Virgiliu._REZULTATELE_LA_DISTANTA_SI_A_TOXICITATII_IN_URMA.pdf132.04 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2013  Duraspace - Feedback