Institutional Repository in Medical Sciences
(IRMS – Nicolae Testemițanu SUMPh)

Compatibility determination of potassium orotate with spironolactone by high-performance liquid chromatography

Show simple item record

dc.contributor.author Mazur, Ecaterina
dc.contributor.author Schmid, Martin
dc.contributor.author Uncu, Livia
dc.date.accessioned 2020-11-10T07:35:38Z
dc.date.available 2020-11-10T07:35:38Z
dc.date.issued 2020-10
dc.identifier.uri http://repository.usmf.md/handle/20.500.12710/12768
dc.identifier.uri https://stiinta.usmf.md/ro/manifestari-stiintifice/zilele-universitatii
dc.description State University of Medicine and Pharmacy "Nicolae Testemiteanu" Chișinău, Republic of Moldova, Congresul consacrat aniversării a 75-a de la fondarea Universității de Stat de Medicină și Farmacie „Nicolae Testemițanu” din Republica Moldova, Ziua internațională a științei pentru pace și dezvoltare en_US
dc.description.abstract Introduction. Nowadays, the number of new fixed-dose combinations (FDCs) is rising significantly. FDC is a medicine that includes two or more active pharmaceutical ingredients (APIs) combined in a single dasage form. Therefore, compatibility determination between APIs in fixed-dose combinations is an indispensable step in the elaboration. To investigate the compatibility of the components of a formulation, techniques, such as X-ray diffraction, FT-IR spectroscopy, high-performance liquid chromatography (HPLC) and thermal analysis (especially differential scanning calorimetry - DSC) are used. The present study is based HPLC High-performance liquid chromatography provides information on possible interactions between APIs and their related interaction products. Purpose. The purpose of the present study was to investigate the compatibility of potassium orotate in combination with spironolactone by the HPLC method. Material and methods. The detection was carried out using Liquid Chromatograph Agilent 1100 equipped with autosampler, UV-VIS detector, applying mobile phase, which consists of acetonitrile and phosphate buffer solution (pH=4.0) ratio in 1:49 and 1:1, at flow rates 1 and 1.5 mL/min, injection volume 20 μL. The study was made on a RP-18 reversed column (250mm long by 4 mm internal diameter, particle size 5μm) and at an isocratic elution method. The APIs (potassium orotate and spironolactone) were provided by Sigma Aldrich, USA. Results. Due to developed method both separation and simultaneous qualitative and quantitative determination of APIs in the mechanical mixture were carried out, using HPLC. Spironolactone: retention time 6.9 min, concentration 98.1% (±0.21); potassium orotate: retention time 3.06 min, concentration 91.67% (±0.15). There were just well-separated symmetrical peaks of APIs and no additional peak in the chromatograms. Conclusions. There is compatibility between APIs. Further studies will be performed by other methods (DSC, FT-IF Spectrometry) to confirm the obtained result. Acknowledgment. We thank the coordinators of the CEEPUS program, especially the “Teaching and learning Bioanalysis” network, for the possibility of accessing mobility CIII-RO-0010-14-1920 and the opportunity to execute works within the Laboratory of Pharmaceutical Chemistry, Faculty of Pharmacy, University of Graz, Austria. en_US
dc.language.iso en en_US
dc.publisher Universitatea de Stat de Medicină şi Farmacie "Nicolae Testemiţanu" en_US
dc.subject HPLC en_US
dc.subject combination en_US
dc.subject potassium orotate en_US
dc.subject spironolactone en_US
dc.title Compatibility determination of potassium orotate with spironolactone by high-performance liquid chromatography en_US
dc.type Other en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics