Institutional Repository in Medical Sciences
(IRMS – Nicolae Testemițanu SUMPh)

Development and validation of the high-pressure liquid chromatography method for propyltiohinotiadiazol dosage

Show simple item record

dc.contributor.author Uncu, Andrei
dc.date.accessioned 2020-11-11T14:28:34Z
dc.date.available 2020-11-11T14:28:34Z
dc.date.issued 2020-10
dc.identifier.uri https://stiinta.usmf.md/ro/manifestari-stiintifice/zilele-universitatii
dc.identifier.uri http://repository.usmf.md/handle/20.500.12710/12894
dc.description Scientific Center for Drug Research Nicolae Testemitanu State University of Medicine and Pharmacy of Republic of Moldova, Congresul consacrat aniversării a 75-a de la fondarea Universității de Stat de Medicină și Farmacie „Nicolae Testemițanu” din Republica Moldova, Ziua internațională a științei pentru pace și dezvoltare en_US
dc.description.abstract INTRODUCTION. Propylthiohinothiadiazole is a thiadiazole derivative with pronounced antimycobacterial action. Substance is researched in order to develop methods of analysis and standardization, analytical documents regulating quality for use as an active principle in the development of pharmaceutical forms. The purpose. Elaboration of the work technique and validation of the HPLC method for dosing propylthiohinothiadiazole. MATERIAL AND METHODS. 3 series of propylthiohinothiadiazole, internal reference standard of 2-(propylthio)-5H-[1,3,4]- thiadiazole[2,3-b]-quinazolin-5-one substance with concentration 99,98%, chromatographic system Shimadzu LC-20AD HPLC with UV-VIS detector, acetonitrile and dimethylsulfoxide of purity grade “pro HPLC analysis” (Sigma Aldrih and Merck), bidistilled purified water. RESULTS. Linearity is proved for concentrations of 5-30 µg/ml, the linear regression equation is y=36472x44580, R²=0.9929. The limit of detection is 0,729 µg/ml and the limit of quantification is 2,210 µg/ml. It was established that the method is accurate (mean recovery values at 80%, 100% and 120% concentration levels were close to 100%. The accuracy of the method was expressed by repeatability and intermediate accuracy. The variation of the chromatographic conditions established that the method is robust. For all validation parameters, RSD was less than 1. CONCLUSIONS. The validation results show that the developed HPLC method is simple, fast, accurate and reproducible. en_US
dc.language.iso en en_US
dc.publisher Universitatea de Stat de Medicină şi Farmacie "Nicolae Testemiţanu" din Republica Moldova en_US
dc.subject HPLC en_US
dc.subject propylthiohinothiadiazole en_US
dc.subject dosing en_US
dc.subject validation en_US
dc.title Development and validation of the high-pressure liquid chromatography method for propyltiohinotiadiazol dosage en_US
dc.type Other en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics