Institutional Repository in Medical Sciences
(IRMS – Nicolae Testemițanu SUMPh)

Aspecte clinice şi tehnice în tratamentul edentaţiei unidentare prin proteze implanto-purtate

Show simple item record

dc.contributor.author Rusu, Vasile
dc.contributor.author Oineagra, Vasile
dc.contributor.author Oineagra, Vadim
dc.contributor.author Rusu, Andrei
dc.date.accessioned 2022-07-12T07:08:26Z
dc.date.available 2022-07-12T07:08:26Z
dc.date.issued 2019
dc.identifier.citation RUSU, Vasile, OINEAGRA, Vasile, OINEAGRA, Vadim, RUSU, Andrei. Aspecte clinice şi tehnice în tratamentul edentaţiei unidentare prin proteze implanto-purtate = Clinical and technical aspects in the treatment of partial edentation by implant. In: Medicina stomatologică = Journal of Stomatological Medicine. 2019, vol. 3(52), pp. 83-90. ISSN 1857-1328. en_US
dc.identifier.issn 1857-1328
dc.identifier.uri https://www.asrm.md/ro/arhiva/revista-medicina-stomatologica-nr-3-2019
dc.identifier.uri http://repository.usmf.md/handle/20.500.12710/21534
dc.description.abstract Rezumat. Este prezentat analiza a trei metode de fixare a protezelor fixe unidentare implantopuratate unde am analizat cantitatea de ciment ce refluează în afara liniei de conexiune dintre abutmentul standart, abutment individual hybrid şi înşurubare, cu ajutorul metodei fotometrice. Acest studiu s-a efectuat pe cadru tripodic, la aceiaşi distanţă, unghi, parametrii, lumină şi folosind aceiaşi cantitate de ciment în fiecare coroană. Calibrarea s-a efectuat cu ajutorul unui analog calibrat. În rezultatul cercetării am observat că cantitatea de ciment ce refluează în afara liniei de conexiune dintre abutmentul standart, abutment individual hybrid şi coroana este diferit. en_US
dc.description.abstract Summary. Was made the analysis of three methods of prosthesis fixing on the implants, where we analyzed the amount of cement reflecting off the connection line between the standard abutment, individual hybrid abutment and screwing, using the photometric method. This study was performed on a tripod frame, at the same distance, angle, parameters, light and using the same amount of cement in each crown. Calibration was performed using a calibrated analog. As a result of the research we noticed that the amount of cement reflecting off the connection line between the standard abutment, individual hybrid abutment and the crown is different. en_US
dc.publisher Asociaţia Stomatologilor din Republica Moldova, Universitatea de Stat de Medicină și Farmacie „Nicolae Testemiţanu“ en_US
dc.relation.ispartof Medicina Stomatologică en_US
dc.subject standard abutment en_US
dc.subject individual hybrid en_US
dc.subject screw en_US
dc.title Aspecte clinice şi tehnice în tratamentul edentaţiei unidentare prin proteze implanto-purtate en_US
dc.title.alternative Clinical and technical aspects in the treatment of partial edentation by implant en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics