Institutional Repository in Medical Sciences
(IRMS – Nicolae Testemițanu SUMPh)

Densitometria oaselor maxilare: studiu retrospectiv de analogare a densităţii optice relativă a clișeelor OPG cu datele periotestometriei

Show simple item record

dc.contributor.author Gumeniuc, Aureliu
dc.date.accessioned 2022-08-30T07:47:39Z
dc.date.available 2022-08-30T07:47:39Z
dc.date.issued 2014
dc.identifier.citation GUMENIUC, Aureliu. Densitometria oaselor maxilare: studiu retrospectiv de analogare a densităţii optice relativă a clișeelor OPG cu datele periotestometriei. In: Medicina stomatologică. 2014, Nr. 3(32), pp. 84-87. ISSN 1857-1328. en_US
dc.identifier.issn 1857-1328
dc.identifier.uri https://www.asrm.md/ro/arhiva/nr-3-33-2014c
dc.identifier.uri http://repository.usmf.md/handle/20.500.12710/21703
dc.description.abstract Rezumat. Studiul densitometric a fost efectuat în baza a 196 de clișee OPG realizate preimplantar. Au fost examinate 327 de zone ale maxilarelor, respectiv pentru aplicarea a 572 implante dentare one piece. Datele obţinute au fost prelucrate statistic prin corelare cu rezultatele primite în studiile anterioare referitor la valorile Periotest® a stabilităţii primare a implantelor imediat după inserarea lor și aprecierea densităţii oaselor maxilarelor în timpul formării neoalveolelor. Rezultatele obţinute au demonstrat o corelaţie inversă puternică între indicii de densitometrie obţinuţi atât faţă de valorile Periotest® a stabilităţii primare (r=-0,74, p<0,001), cât și a densităţii oaselor maxilarelor apreciate intraoperator (r=-0,71, p<0,001). en_US
dc.description.abstract Summary. The study of bone density was based on 196 orthopantomograms made before implant placement. 327 maxillary zones had been examined for the insertion of 572 one-piece dental implants. The received data had been statistically processed by correlating the previous results of Periotest® values of the primary stability with the bone density assessment during implant insertion procedures. The obtained results have shown a strong inverse correlation between the obtained densitometry values both with the Periotest® values of primary stability (r=-0,74, p<0,001), as well as with the bone density appreciated during surgery(r=-0,71, p<0,001). en_US
dc.language.iso ro en_US
dc.publisher Asociaţia Stomatologilor din Republica Moldova, Universitatea de Stat de Medicină și Farmacie „Nicolae Testemiţanu“ en_US
dc.relation.ispartof Medicina Stomatologică en_US
dc.subject densitometry en_US
dc.subject one-piece dental implant en_US
dc.subject Periotest® values en_US
dc.subject primary stability en_US
dc.title Densitometria oaselor maxilare: studiu retrospectiv de analogare a densităţii optice relativă a clișeelor OPG cu datele periotestometriei en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics