dc.contributor.author |
Melnic, Svetlana |
|
dc.contributor.author |
Motelica, Gabriela |
|
dc.contributor.author |
Cheptănaru, Olga |
|
dc.contributor.author |
Poștaru, Cristina |
|
dc.contributor.author |
Ivasiuc, Irina |
|
dc.contributor.author |
Chele, Nicolae |
|
dc.date.accessioned |
2022-10-04T07:37:43Z |
|
dc.date.available |
2022-10-04T07:37:43Z |
|
dc.date.issued |
2016 |
|
dc.identifier.citation |
MELNIC, Svetlana, MOTELICA, Gabriela, CHEPTĂNARU, Olga, et al. Conceptele încărcării implantelor dentare = Concepts of loading the dental implants. In: Medicina stomatologică = Journal of Stomatological Medicine. 2016, nr. 3(40), pp. 91-92. ISSN 1857-1328. |
en_US |
dc.identifier.issn |
1857-1328 |
|
dc.identifier.uri |
https://www.asrm.md/ro/arhiva/nr-3-40-2016 |
|
dc.identifier.uri |
http://repository.usmf.md/handle/20.500.12710/21871 |
|
dc.description.abstract |
Introducere:
Implantologia dentară a fost supusă unor schimbări dramatice încă în anul
1970 de la apariţia conceptului osteointegrării. Progresele tratamentului implanto-
protetic au inclus modificarea suprafeţelor implantelor din titan, prelucrarea
suprafeţelor cu substanţe biologic active, proiectarea filetului, diverse tipuri de
abutmente protetice și protocoale de încărcare a implantelor dentare.
Scopul lucrării: optimizarea protocoalelor de încărcare a implantelor dentare.
Materiale și metode: în scopul planificării tratamentului implanto-protetic,
va fi necesară o evaluare clinică amănunţită, care ar trebui să includă examenul
exo- și endobucal complex cu evaluarea liniei zâmbetului, morfologiei gingivale,
relaţiilor intermaxilare, stării și poziţiei marginii gingivale faţă de dinţii adiacenţi,
precum starea ţesutului osos. Și este important să știm că orice modificare poate
compromite rezultatul final cu modificarea ocluziei și fizionomiei.
Rezultate
Conform unor cercetări, s-a constatat că în încărcarea imediată a implantelor
denatare remodelarea osoasă și densitatea osoasă sunt în creștere comparativ cu
implanturile încărcate tardiv. Brunski et al., a raportat că la micromișcările de 100
μm se formează interfaţa directă os-implant, iar dacă sunt mai mult de 150 μm
duce la formarea ţesutului fibros. Canullo et al., a demonstrat că remodelarea osoasă
a fost mai mică în cazurile încărcării imediate, decât în încărcarea întârziată. În
ciuda acestei limite în zona de vindecare, s-a arătat că osul poate umple defectele
osoase din jurul implanturilor dentare, cu diametru mai mare de 1.5-2.0 mm.
Discuţii și concluzii
Diametrul implantului și lungimea sunt adesea subliniate ca valori ce dau o
perspectivă asupra interfeţei os-imlant. Avila et al., a descris, că pentru fiecare creștere
de 3mm în lungime pentru implantele cilindrice dincolo de 10 mm, puteţi
crește suprafaţa os-implant cu mai mult de 20%. Schnitman et al., a observat o
rată de eșec de 50% în încărcarea imediată a implantelor dentare cu lungimea mai
puţin de 10 mm. Balshi și Golfinger au raportat că 75% din eșecurile încărcării
implantelor dentare sunt parafuncţiile pacienţilor, dinamica musculară crescută și
coroanele dentare supradimensionate. |
en_US |
dc.description.abstract |
Introduction:
Dental implantology has undergone dramatic changes since 1970 by the emergence
of the concept of osseointegration. Progress prosthetic implant treatment
included change of titanium implant surfaces, surface treatment with biologically
active substances thread design, various types of abutments and prosthetic protocols
for loading of dental implants.
The purpose of the work: optimizing protocols for loading of dental implants.
Materials and Methods: in order implant-supported prosthetic treatment
planning will require a thorough clinical evaluation, which should include complex:
extraoral and intraoral examination, assessment smile line, gingival morphology,
intermaxillary relations, state and position of adjacent teeth and the bone
tissue condition. And it is important to know that any change can compromise the
outcome by changing occlusion and physiognomy.
Results:
According to some research, it has been found that immediate loading of the
implant in bone remodeling and bone density denatare are higher compared to
implants loaded late. Brunski et al., it was reported that 100 μm micromovements
formed implant-bone contact, and if more than 150 μm leads to the formation offibrous tissue. Canullo et al., demonstrated that bone
remodeling was lower in the immediate loading, than
in the delayed loading. Despite this limitation in the
area of healing, it has been shown that bone can fill
bone defects surrounding the tooth implants with a
diameter greater than 1.5-2.0 mm.
Discussion and conclusions:
Implant diameter and length are often highlighted
as values that give insight imlant-bone interface. Avila et al., described that for every increase of 3mm
in length beyond 10 mm cylindrical implants, bone-
implant surface can increase by more than 20%.
Schnitman et al., noted a failure rate of 50% in immediate
loading of dental implants with length less
than 10 mm. Balshi and Golfinger reported that 75%
of failures loading dental implants are parafunctions
patients, increased muscle growth and oversized of
dental crowns. |
en_US |
dc.publisher |
Asociaţia Stomatologilor din Republica Moldova, Universitatea de Stat de Medicină și Farmacie „Nicolae Testemiţanu“ |
en_US |
dc.relation.ispartof |
Medicina Stomatologică |
en_US |
dc.subject |
prosthetic abutments |
en_US |
dc.subject |
loading protocols |
en_US |
dc.subject |
implant-supported prosthetic treatment |
en_US |
dc.title |
Conceptele încărcării implantelor dentare |
en_US |
dc.title.alternative |
Concepts of loading the dental implants |
en_US |
dc.type |
Other |
en_US |