Institutional Repository in Medical Sciences
(IRMS – Nicolae Testemițanu SUMPh)

Eficiența lentilelor de contact sclerale la pacienții cu keratoconus

Show simple item record

dc.contributor.author Popușoi, Cristina
dc.contributor.author Bîlba, Rodica
dc.contributor.author Chiriac, Vera
dc.contributor.author Coșula, Cristina
dc.contributor.author Curca, Stelian
dc.date.accessioned 2024-12-19T12:50:28Z
dc.date.accessioned 2024-12-22T08:35:28Z
dc.date.available 2024-12-19T12:50:28Z
dc.date.available 2024-12-22T08:35:28Z
dc.date.issued 2024
dc.identifier.citation POPUȘOI, Cristina; BÎLBA, Rodica; CHIRIAC, Vera; COȘULA, Cristina; CURCA, Stelian. Eficiența lentilelor de contact sclerale la pacienții cu keratoconus = The efficiency of scleral contact lenses in patients with keratoconus. In: Revista de Ştiinţe ale Sănătăţii din Moldova = Moldovan Journal of Health Sciences. 2024, vol. 11, Nr. 3, anexa 2, p. 577. ISSN 2345-1467. en_US
dc.identifier.issn 2345-1467
dc.identifier.uri https://cercetare.usmf.md/sites/default/files/inline-files/MJHS_11_3_2024_anexa2__site.pdf
dc.identifier.uri http://repository.usmf.md/handle/20.500.12710/29587
dc.description Universitatea de Stat de Medicină şi Farmacie „Nicolae Testemiţanu”, Chişinău, Republica Moldova en_US
dc.description.abstract Introducere. Keratoconus este o afecțiune progresivă a ochilor caracterizată prin subțierea și deformarea anormală în formă de con a corneei. Acest lucru duce la distorsiuni vizuale semnificative și la o sensibilitate crescută la lumină. Fără un tratament adecvat, keratoconus poate afecta în mod sever calitatea vieții pacienților. Lentilele de contact sclerale au devenit o opțiune populară pentru gestionarea acestei condiții datorită capacității lor de a oferi o suprafață optică netedă și de a corecta iregularitățile corneene. Obiectiv. Evaluarea eficacității lentilelor de contact sclerale pentru corecția ametropiei la pacienții cu keratoconus. Material și metode. În studiu au fost incluși 49 de pacienți (93 de ochi) cu keratoconus stabilizat după procedura de Cross-linking epi-on. Toate cazurile clinice au fost divizate în trei loturi în dependență de stadiul keratoconusului, stadiul I (n-8 ochi), stadiul II (n-24 ochi), stadiul III (n-61 ochi). Toți pacienții au aplicat lentile de contact sclerale timp de 12 luni. Rezu ltate. 1. Dinamica comparativă a acuității vizuale în funcție de stadiul keratoconusului a demonstrat că la pacienții cu stadiul I nu există modificări semnificative dintre AVMC în ochelari și cea în lentile de contact sclerale, ceea ce le oferă acestora o alegere mai largă a metodei de corecție optică. Acuitatea vizuală corijată cu lentile de contact sclerale la pacienții cu keratoconus stadiul II și stadiul III este cu 0,43 și 0,49 mai mare decât la pacienții care au aplicat corecție optică aeriană. Concluzii. 1. Pe parcursul utilizării lentilelor sclerale s-a înregistrat îmbunătățirea și stabilizarea calității lacrimii. Timpul de rupere a filmului lacrimal s-a majorat statistic semnificativ de la 7,02 sec. până la 10,4 sec în decursul unui an. 2. Înălțimea meniscului lacrimal a avut o valoare statistic stabilă cu modificări de la 0,19 mm până la 0,23 mm. 3.Calitatea vieții la pacienții cu keratoconus care poartă lentile de contact sclerale s-a schimbat radical. Lentilele sclerale le oferă pacienților un confort considerabil, îmbunătățesc calitatea vieții pacienților prin modul în care își percep imaginea, de asemenea practicarea sportului și diferitor activități, precum și satisfacția generală privind vă zul. ro_RO
dc.description.abstract Background. Keratoconus is a progressive eye condition characterized by thinning and abnormal cone-shaped deformation of the cornea. This leads to significant visual distortions and increased sensitivity to light. Without ade quate treatment, keratoconus can severely impact patients’ quality of life. Scleral contact lenses have become a popular option for managing this condition due to their ability to provide a smooth optical surface and correct corneal irregularities. Objective. To evaluate the efficacy of scleral contact lenses for ametropia correction in patients with keratoconus. Material and methods. The study included 49 patients (93 eyes) with stabilized keratoconus following the epi-on Cross-linking procedure. All clinical cases were divided into three groups based on the stage of keratoconus: stage I (8 eyes), stage II (24 eyes), stage III (61 eyes). All patients wore scleral contact lenses for 12 months. Re sults. Comparative dynamics of visual acuity depending on the stage of keratoconus demonstrated that patients with stage I showed no significant differences between corrected visual acuity with glasses and that with scleral contact lens es, providing them with a wider choice of optical correction methods. Corrected visual acuity with scleral contact lenses in patients with stage II and stage III keratoconus was 0.43 and 0.49 higher, respectively, than in patients using optical correction with glasses. Conclusions. During the use of scleral lenses, improvement and stabilization of tear quality were recorded. The tear film breakup time increased signifi cantly from 7.02 seconds to 10.4 seconds over the course of a year. 2.The height of the tear meniscus had a statistically stable value, changing from 0.19 mm to 0.23 mm. 3. The quality of life for patients with keratoconus wearing scleral contact lenses changed dramatically. Scleral lenses provide considerable comfort, enhance the quality of life by improving the patients’ visual perception, enable them to engage in sports and various activities, and increase overall satisfaction with their vision. en_US
dc.publisher Instituţia Publică Universitatea de Stat de Medicină şi Farmacie „Nicolae Testemiţanu” din Republica Moldova en_US
dc.relation.ispartof Revista de Științe ale Sănătății din Moldova = Moldovan Journal of Health Sciences en_US
dc.subject keratoconus en_US
dc.subject scleral contact lenses en_US
dc.subject visual acuity en_US
dc.subject ocular comfort en_US
dc.subject optical correction with glasses en_US
dc.subject stage of keratoconus en_US
dc.subject keratoconus management en_US
dc.title Eficiența lentilelor de contact sclerale la pacienții cu keratoconus ro_RO
dc.title.alternative The efficiency of scleral contact lenses in patients with keratoconus en_US
dc.type Other en_US