Institutional Repository in Medical Sciences
(IRMS – Nicolae Testemițanu SUMPh)

Analysis of spironolactone in compound powder by ultraviolet-visible spectrophotometry

Show simple item record

dc.contributor.author Mazur, Ecaterina
dc.date.accessioned 2025-03-13T11:48:47Z
dc.date.available 2025-03-13T11:48:47Z
dc.date.issued 2024
dc.identifier.citation MAZUR, Ecaterina. Analysis of spironolactone in compound powder by ultraviolet-visible spectrophotometry. In: Revista de Ştiinţe ale Sănătăţii din Moldova = Moldovan Journal of Health Sciences. 2024, vol. 11, nr. 4, pp. 38-43. ISSN 2345-1467. DOI: https://doi.org/10.52645/MJHS.2024.4.06 en_US
dc.identifier.issn 2345-1467
dc.identifier.uri https://mjhs.md/sites/default/files/2024-12/MJHS_11_4_2024.pdf
dc.identifier.uri https://repository.usmf.md/handle/20.500.12710/30074
dc.identifier.uri https://doi.org/10.52645/MJHS.2024.4.06
dc.description.abstract Introduction. Spironolactone (Spir) is a selective and competitive antagonist of aldosterone that increases the excretion of water and sodium while decreasing the excretion of potassium (K+ sparing diuretic). The substance was studied to develop qualitative and quantitative methods of analysis and to validate them according to documents regulating the quality of active pharmaceutical ingredients in the development of pharmaceutical forms. Material and methods. A new dosage form (powder) with Spir was developed and analyzed by a spectrophotometry method using a UV-Vis spectrophotometer (Agilent 8453, USA) with 10.0 mm matched quartz cells at 238±2nm, with methanol as the blank. The method was validated for specificity, linearity, precision, accuracy, robustness, LOD and LOQ. Results. The method was found to be linear in the drug concentration range of 5.0 to 30.0 μg/ml, with a correlation coefficient (R2 ) of 0.9994 for Spir. The LOD of Spir was 0.5 μg/ml and the LOQ was 1.4 μg/ml, indicating the method’s sensitivity. The method was established as accurate (mean recovery values of concentration at 80%, 100%, 120% ranging between 99.9 and 101.7%). Repeatability precision and intermediate precision %RSD values amongst six sample solutions were from 0.13% to 0.25% for Spir (less than 2%). The accuracy (recovery) ranged between 99.9% and 101.7%, with standard deviations ranging from 0.08% to 0.17%. Conclusions. In the presence of common excipients, such as microcrystalline cellulose, lactose monohydrate, and stearic acid, no interferences were observed. This method was found to be suitable for the routine analysis of Spir from the newly developed pharmaceutical form. en_US
dc.language.iso en en_US
dc.publisher Instituţia Publică Universitatea de Stat de Medicină şi Farmacie „Nicolae Testemiţanu” din Republica Moldova en_US
dc.relation.ispartof Revista de Ştiinţe ale Sănătăţii din Moldova = Moldovan Journal of Health Sciences en_US
dc.subject spironolactone en_US
dc.subject UV-Vis spectrophotometry en_US
dc.subject validation en_US
dc.subject.ddc UDC: 615.254.1.012/.014:543.422.3 en_US
dc.title Analysis of spironolactone in compound powder by ultraviolet-visible spectrophotometry en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics