Institutional Repository in Medical Sciences
(IRMS – Nicolae Testemițanu SUMPh)

The stable-functional osteosynthesis of clavicular fractures with external fixator

Show simple item record

dc.contributor.author Roșu, Gheorghe
dc.date.accessioned 2019-09-11T12:57:09Z
dc.date.available 2019-09-11T12:57:09Z
dc.date.issued 2019-03
dc.identifier.citation ROŞU, Gheorghe. The stable-functional osteosynthesis of clavicular fractures with external fixator. In: The Moldovan Medical Journal. 2019, vol. 62, no 1, pp. 9-12. ISSN 2537-6373. DOI: 10.5281/zenodo.2589994 en_US
dc.identifier.issn 2537-6373
dc.identifier.issn 2537-6381
dc.identifier.uri http://repository.usmf.md/handle/20.500.12710/6755
dc.identifier.uri https://doi.org/10.5281/zenodo.2589994
dc.identifier.uri http://moldmedjournal.md/wp-content/uploads/2019/03/Moldovan-Med-J-Vol-62-No-1-Full-Issue.pdf
dc.description Department of Trauma, Emergency Medicine Institute, Chisinau, District Hospital Rascani, the Republic of Moldova en_US
dc.description.abstract Background: Over the past two decades has been paid insufficient attention to the treatment of patients with clavicle fractures. Analysis is of the recent available literature and the personal practice allow us to have a special position to this issue, solving the problem of the clavicle fractures treatment with a new and more efficient method. Material and methods: For a better deduction and appreciation of the fracture fixation methods results we established a task based on the effectiveness evaluation of the external fixator utilization as a way for a stable osteosynthesis of the fragments performance. It was tested experimentally the efficacy of clavicle fragments fixation with different fixators. The experiment was performed at 30 anatomical specimens of clavicle aged from 38 to 70 years. The mechanical force of the osteosynthesised fragments fixation at flexion and stretching was appreciated in the Alfred G. Amsler German machine with a deviation from 0 to 50 Kn/cm and the capacity of a unit equal to 0.5 Kn/cm. Results: After the application of the stable-functional osteosynthesis method in clavicle fractures treatment with the external fixator’s help, the experimental samples prove objectively the qualities of the proposed fixator, which has an essential priority in the mechanical force of fixing the fragments compared to the traditional fixators used in most cases at the patients with clavicle fractures. Conclusions: The new method of stable-functional osteosynthesis of the clavicle fractures by using the external fixator, which is simple in assembly and manufacture, excludes the shortcomings of the traditional methods of surgical treatment and allows its application at any level of specialized surgical aid. en_US
dc.language.iso en en_US
dc.publisher The Scientific Medical Association of the Republic of Moldova en_US
dc.relation.ispartof The Moldovan Medical Journal
dc.subject osteosynthesis en_US
dc.subject external fixation en_US
dc.subject clavicular fractures en_US
dc.subject.ddc UDC: 616.717.2-001.5-089.22:615.465
dc.subject.mesh Clavicle--injuries en_US
dc.subject.mesh Fractures, Bone--surgery en_US
dc.subject.mesh Fracture Fixation--methods en_US
dc.subject.mesh External Fixators en_US
dc.subject.mesh Biomechanical Phenomena en_US
dc.title The stable-functional osteosynthesis of clavicular fractures with external fixator en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics