Title: | The flap thickness outcomes with new dual femtosecond laser platform |
Authors: | Bilgehan, Sezgin Asena |
Issue Date: | 2021 |
Publisher: | Black Sea Ophthalmological Society, Ophthalmological Association from Moldova, Nicolae Testemitanu State University of Medicine and Pharmacy of the Republic of Moldova |
Citation: | BILGEHAN, Sezgin Asena. The flap thickness outcomes with new dual femtosecond laser platform. In: 19th Black Sea Ophthalmological Society Congress, September 24-26, 2021, Chisinau, Republic of Moldova: abstract book, p. 26. |
Abstract: | Purpose: To evaluate flap thickness in femtosecond (FS) laser assisted LASIK operation for
myopia performed with new LenSx dual platform using curved interface.
Materials and methods: Fifty eyes of 26 patients (mean±SD age: 26.9±8.1 years, 53.8% were
females) with myopia or myopic astigmatism operated with FS laser-assisted LASIK were
evaluated in this study. Data on patient demographics, preoperative and postoperative keratometric
and aberrometric parameters and flap thickness outcome including mean central flap thickness
(MCFT), mean total flap thickness (MTFT), intra-FT range and flap thickness homogeneity (FTH)
were recorded.
Results: Flap thickness assessment revealed median values for MCFT to be 123 µm (range, 109
to 134), while MTFT was 123 µm (range, 109 to 133.7), Intra-FT range was 4.0 µm (ranged, 1 to
6) and FTH was -2 µm (range, -6 to 2). Overall flap thickness was thicker than planned by +3.0
μm (minimum, 109.0 μm with a −11.0 μm average difference and maximum, 133.7 μm with a
+13.7 μm difference) with an average thickness standard deviation of 6.6 μm.
Conclusions: In conclusion, our findings related to FS laser assisted LASIK surgery for myopia
with new LenSx dual platform using curved interface revealed favorable corneal flap thickness
outcome in terms of closeness of flap thickness to the intended value and low intra-flap range.
Thus, our findings emphasize the likelihood of planning and producing more successful LASIK
outcomes in terms of consistency and predictability of corneal flap thickness with use of new
LenSx dual platform. |
metadata.dc.relation.ispartof: | 19th Black Sea Ophthalmological Society Congress, September 24-26, 2021 Chisinau, Republic of Moldova |
URI: | https://aom.md/wp-content/uploads/2021/10/ABSTRACT-BOOK_web.pdf http://repository.usmf.md/handle/20.500.12710/24057 |
Appears in Collections: | 19th Black Sea Ophthalmological Society Congress, September 24-26, 2021 Chisinau, Republic of Moldova
|
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
|