Institutional Repository in Medical Sciences
(IRMS – Nicolae Testemițanu SUMPh)

Reconstruction of the contact point with the palodent V3 system.

Show simple item record

dc.contributor.author Borta, Ecaterina
dc.date.accessioned 2020-07-01T17:11:02Z
dc.date.available 2020-07-01T17:11:02Z
dc.date.issued 2018
dc.identifier.citation BORTA, Ecaterina. Reconstruction of the contact point with the palodent V3 system. In: MedEspera: the 7th Internat. Medical Congress for Students and Young Doctors: abstract book. Chișinău: S. n., 2018, p. 242. en_US
dc.identifier.uri https://medespera.asr.md/wp-content/uploads/Abastract-Book-2018.pdf
dc.identifier.uri http://repository.usmf.md/handle/20.500.12710/10813
dc.description Nicolae Testemitanu State University of Medicine and Pharmacy of the Republic of Moldova en_US
dc.description.abstract Introduction. The contact point has a very important role in protecting the interdental papillae; it spreads uniformly the masticatory pressure that is developed during the mastication act. Aim of the study. To achieve a three-dimensional restoration of the proximal surface with punctiform contact. Materials and methods. The study was based on the use of matrices with anatomical relief from the Palodent V3 system, with the control of matrix adherence at the cervical and lateral sides on clinical simulators. Reconstruction of the contact point on the clinical simulators was performed by the direct method, using atraumatic pins, anatomic relief matrices and strong Ni-Ti rings. The titanium nickel rings are long lasting, surpassing the stainless steel rings. The strength of the ring retainer improves the retention in the tooth. Rings and wedges can overlap and work well in complicated class II restorations, such as those with a missing cusp. The matrices, wedges and protection wedges are anatomically designed to provide a better seal and narrower contacts. Results. The Palodent V3 system components work together to seal and shape the restoration, minimizing the required time to finish it, as well as the possibility to re-do the restoration due to a poor contact. The system can be configured for multiple restorations at once, and the WedgeGuard provides added efficiency by protecting the adjacent tooth, allowing the clinician to prepare the cavity without complications. The tines on the rings help to provide excellent retention on the tooth and the system seals the restoration to minimize the amount of finishing required. It was noticed that adapting the wedges to the matrix leads to firm gingival closure and firm predictable contacts. The narrow rings adapt the matrix to the lateral teeth and enlarge the interdental space at the micron level. Conclusions. The use of the Palodent V3 system allows us to get a predictable, easy and fast result. en_US
dc.language.iso en en_US
dc.publisher MedEspera en_US
dc.subject contact point en_US
dc.subject wedge en_US
dc.subject matrix en_US
dc.subject rings en_US
dc.title Reconstruction of the contact point with the palodent V3 system. en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

  • MedEspera 2018
    The 7th International Medical Congress for Students and Young Doctors, May 3-5, 2018

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics