Institutional Repository in Medical Sciences
(IRMS – Nicolae Testemițanu SUMPh)

Standardized foam for sclerotherapy of varicose veins of lower limbs: is it better?

Show simple item record

dc.contributor.author Ursoi, Cristina
dc.contributor.author Turcan, Valeria
dc.date.accessioned 2020-10-27T11:26:13Z
dc.date.available 2020-10-27T11:26:13Z
dc.date.issued 2016
dc.identifier.citation URSOI, Cristina, TURCAN, Valeria. Standardized foam for sclerotherapy of varicose veins of lower limbs: is it better? In: MedEspera: the 6th Internat. Medical Congress for Students and Young Doctors: abstract book. Chișinău: S. n., 2016, p. 160. en_US
dc.identifier.uri http://repository.usmf.md/handle/20.500.12710/12347
dc.description Nicolae Testemitanu State University of Medicine and Pharmacy, Chisinau, Republic of Moldova, The 6th International Medical Congress for Students and Young Doctors, May 12-14, 2016 en_US
dc.description.abstract Introduction: Nowadays the foam scleroterapy is becoming the top choice of the majority of vascular surgeons for varicose disease treatment, altough a standartized method of producing SF has not been chosen yet. Aims: To appreciate the difference between the half-life of the sclerosant foam (SF) obtained by using different types of syringes connected by a two-way connector, and the one obtained by using the Kreussler Pharma Easy Foam Kit. Methods: In CCGS labaratory of USMF,,Nicolae Testemitanu” an experimental study was performed. By using Trombovar 3% and Etoxisclerol 3%, together with room air, different brands and volumes of syringes, siliconized and unsiliconized syringes, a two-way connector and Kreussler Pharma Easy Foam Kit, SF was obtained. The liquid-to-gas ratio was 1:4, with 20 passages. Results: The SF hal-life varried unsignifically when using both Trombovar 3% and Etoxisclerol 3%, as well as using Kreussler Pharma Easy Foam Kit did not increase the SF half-life, compared to the syringes connected by a two-way connector. The volume of the syringes used in the experimental study, had no influence on the SF half-life. However, the unsyliconized syringes seem to potentiate the durability of the SF. Conclusion: SF formation is greatly influenced by the choice of the types of syringes, also unsiliconized syringes are to be preferred for obtaining of SF. en_US
dc.language.iso en en_US
dc.publisher MedEspera en_US
dc.title Standardized foam for sclerotherapy of varicose veins of lower limbs: is it better? en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

  • MedEspera 2016
    The 6th International Medical Congress for Students and Young Doctors, May 12-14, 2016

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics