Institutional Repository in Medical Sciences
(IRMS – Nicolae Testemițanu SUMPh)

Dozarea concomitentă a m-crezolului și a insulinei în produsul farmaceutic Humulin R

Show simple item record

dc.contributor.author Babileva, Anastasia
dc.contributor.author Valica, Vladimir
dc.contributor.author Bibire, Nela
dc.contributor.author Uncu, Livia
dc.date.accessioned 2021-03-26T08:38:40Z
dc.date.available 2021-03-26T08:38:40Z
dc.date.issued 2016
dc.identifier.citation BABILEVA, Anastasia, VALICA, Vladimir, BIBIRE, Nela, UNCU, Livia. Dozarea concomitentă a m-crezolului și a insulinei în produsul farmaceutic Humulin R. In: Revista Farmaceutică a Moldovei. 2016, nr. 1-4, pp. 55-58. ISSN 1812-5077. en_US
dc.identifier.issn 1812-5077
dc.identifier.uri http://repository.usmf.md/handle/20.500.12710/16351
dc.description Centrul Științific al Medicamentului, IP USMF „Nicolae Testemițanu”, Republica Moldova, Catedra Chimie farmaceutică și toxicologică, IP USMF „Nicolae Testemițanu”, Republica Moldova, Universitatea de medicină și Farmacie ”Grigore T. Popa”, Iași, România en_US
dc.description.abstract Rezumat. A fost modificată și testată metoda HPLC de determinare concomitentă a m-crezolului și a insulinei în produsul farmaceutic Humulin R. Modificările efectuate în tehnica de lucru nu au influențat asupra exactității metodei, iar rezultatele dozării arată, că conținutul de insulină și m-crezol în preparatul Humulin R se încadrează în limitele stabilite de către Farmacopeea Europeană ed. 8.0 și specificațiile de calitate. Ca rezultat, s-a realizat un avantaj plauzibil pentru analizele de rutină a preparatelor insulinice – micșorarea timpului analizei de două ori. Tehnica de lucru modificată și testată poate fi utilizată pentru evaluarea calității preparatelor insulinice prezente pe piața farmaceutică a Republicii Moldova. en_US
dc.description.abstract Abstract. It was modified and tested the HPLC method for simultaneous determination of m-cresol and insulin in Humulin R. The changes, that were made in working technique, did not interfere on the accuracy of the method, and the results show that insulin content and m-cresol in Humulin R preparation is within the limits set by the European Pharmacopoeia ed. 8.0 and quality specifications. As a result, an advantage has been achieved for routine analysis of preparations of insulin – shortening twice the time of analysis. Modified and tested technique can be used to assess the quality of preparations of insulin in the pharmaceutical market of Moldova. en_US
dc.language.iso ro en_US
dc.publisher Asociația Farmaciștilor din Republica Moldova en_US
dc.relation.ispartof Revista Farmaceutică a Moldovei en_US
dc.subject m-cresol en_US
dc.subject insulin en_US
dc.subject HPLC method en_US
dc.title Dozarea concomitentă a m-crezolului și a insulinei în produsul farmaceutic Humulin R en_US
dc.title.alternative Simultaneous determination of m-cresol and insulin in Humulin R en_US
dc.type Other en_US


Files in this item

This item appears in the following Collection(s)

  • Revista Farmaceutică a Moldovei Nr. 1-4, 2016
    Materialele Conferinței științifice cu participare internațională „De la design-ul medicamentului la calitate și inofensivitate” în memoria profesorului Filip Babilev „80 ani de la naștere”, 11 Noiembrie 2016, Chișinău, Republica Moldova

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics